ACCURACY OF RIGHT VENTRICULAR OUTPUT ESTIMATED BY DOPPLER ECHOCARDIOGRAPHY IN THE SHEEP FETUS

被引:11
作者
SHIRAISHI, H
SILVERMAN, NH
RUDOLPH, AM
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT PEDIAT,M-342A,BOX 0214,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,CARDIOVASC RES INST,SAN FRANCISCO,CA 94143
关键词
CARDIAC OUTPUT; TRANSIT-TIME ULTRASONIC FLOWMETER; SHEEP FETUS;
D O I
10.1016/S0002-9378(12)90851-0
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: Our goal was to determine whether Doppler ultrasonographic estimation of fetal right ventricular output was accurate enough to evaluate fetal cardiac performance before the technique can be applied with confidence to the human fetus. The accuracy of this method has not been validated experimentally. STUDY DESIGN: We compared the right ventricular output measured by Doppler echocardiography with that determined from a transit-time ultrasonic flowmeter placed around the fetal pulmonary trunk and to that determined by microsphere technique. We obtained 72 Doppler flow measurements and 16 microsphere flow measurements in six fetuses. RESULTS: There was a fair correlation between cardiac output estimated by Doppler echocardiography performed transabdominally and that determined by a transit-time flowmeter (r = 0.76). The correlation was excellent when Doppler echocardiography was performed by the transuterine approach (r = 0.94). There was also an excellent correlation between right ventricular output determined by a transit-time flowmeter and that by microsphere technique (r = 0.94). CONCLUSION: Doppler echocardiographic estimation of fetal right ventricular cardiac output is thus feasible and accurate.
引用
收藏
页码:947 / 953
页数:7
相关论文
共 16 条
  • [1] ALLAN LD, 1987, BRIT HEART J, V57, P528
  • [2] QUANTITATING ERROR IN BLOOD-FLOW MEASUREMENTS WITH RADIOACTIVE MICROSPHERES
    AUSTIN, RE
    HAUCK, WW
    ALDEA, GS
    FLYNN, AE
    COGGINS, DL
    HOFFMAN, JIE
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (01): : H280 - H288
  • [3] BARNES RJ, 1983, J PHYSL, V35, P2
  • [4] FETAL CARDIAC-OUTPUT ESTIMATED BY DOPPLER ECHOCARDIOGRAPHY DURING MIDGESTATION AND LATE GESTATION
    DESMEDT, MCH
    VISSER, GHA
    MEIJBOOM, EJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (04) : 338 - 342
  • [5] HARTMAN J, 1985, PHARMACOLOGIST, V27, P217
  • [6] BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED PARTICLES
    HEYMANN, MA
    PAYNE, BD
    HOFFMAN, JIE
    RUDOLPH, AM
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (01) : 55 - 79
  • [7] EFFECT OF SAMPLE VOLUME LOCATION ON PULSED DOPPLER DIASTOLIC FLOW PARAMETERS IN NEWBORN-INFANTS
    JOHNSON, GL
    MOFFETT, CB
    JURNALOV, CD
    NOONAN, JA
    [J]. PEDIATRIC CARDIOLOGY, 1988, 9 (04) : 221 - 224
  • [8] EFFECTS OF HEART-RATE ON VENTRICULAR SIZE, STROKE VOLUME, AND OUTPUT IN THE NORMAL HUMAN-FETUS - A PROSPECTIVE DOPPLER ECHOCARDIOGRAPHIC STUDY
    KENNY, J
    PLAPPERT, T
    DOUBILET, P
    SALZMAN, D
    SUTTON, MGS
    [J]. CIRCULATION, 1987, 76 (01) : 52 - 58
  • [9] DOPPLER ECHOCARDIOGRAPHIC COMPARISON OF FLOWS DISTAL TO THE 4 CARDIAC VALVES
    LOEBER, CP
    GOLDBERG, SJ
    ALLEN, HD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (02) : 268 - 272
  • [10] VALIDATION OF THERMAL TECHNIQUES FOR MEASUREMENT OF PELVIC ORGAN BLOOD FLOWS IN THE NONPREGNANT SHEEP - COMPARISON WITH TRANSIT-TIME ULTRASONIC AND MICROSPHERE MEASUREMENTS OF BLOOD-FLOW
    RANDALL, NJ
    BEARD, RW
    SUTHERLAND, IA
    FIGUEROA, JP
    DROST, CJ
    NATHANIELSZ, PW
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1988, 158 (03) : 651 - 658