SYSTEM FOR FLOW SORTING CHROMOSOMES ON THE BASIS OF PULSE SHAPE

被引:14
作者
BARTHOLDI, MF
PARSON, JD
ALBRIGHT, KA
CRAM, LS
机构
[1] Life Sciences Division, Los Alamos National Laboratory, Los Alamos, New Mexico
来源
CYTOMETRY | 1990年 / 11卷 / 01期
关键词
centromeric index; Chinese hamster chromosomes; Chromosome sorting;
D O I
10.1002/cyto.990110119
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sorting on the basis of the complex features resolved by chromosome slit‐scan analysis requires rapid and flexible pulse shape acquisition and processing for determining sort decisions before droplet breakoff. Fluorescence scans of chromosome morphology contain centromeric index and banding information suitable for chromosome classification, but these scans are often characterized by variability in length and height and require sophisticated data processing procedures for identification. Setting sort criteria on such complex morphological data requires digitization and subsequent computation by an algorithm tolerant of variations in overall pulse shape. We demonstrate here the capability to sort individual chromosomes based on their morphological features measured by slit‐scan flow cytometry. To do this we have constructed a sort controller capable of acquiring an 128 byte chromosome waveform and executing a series of numerical computations resulting in an area‐based centromeric index sort decision in less than 2 ms. The system is configured in a NOVIX microprocessor, programmed in FORTH, and interfaced to a slit‐scan flow cytometer data acquisition system. An advantage of this configuration is direct control over the machine state during program execution for minimal processing time. Examples of flow sorted chromosomes are shown with their corresponding fluorescence pulse shapes. Copyright © 1990 Wiley‐Liss, Inc.
引用
收藏
页码:165 / 172
页数:8
相关论文
共 16 条
[1]   AUTOMATED CELL SORTING WITH FLOW SYSTEMS [J].
ARNDTJOVIN, DJ ;
JOVIN, TM .
ANNUAL REVIEW OF BIOPHYSICS AND BIOENGINEERING, 1978, 7 :527-558
[2]  
ARNDTJOVIN DJ, 1974, J HSITOCHEM CYTOCHEM, V7, P622
[3]   CHROMOSOME ANALYSIS BY HIGH ILLUMINATION FLOW-CYTOMETRY [J].
BARTHOLDI, MF ;
SINCLAIR, DC ;
CRAM, LS .
CYTOMETRY, 1983, 3 (06) :395-401
[4]   CHROMOSOME-BANDING ANALYSIS BY SLIT-SCAN FLOW-CYTOMETRY [J].
BARTHOLDI, MF ;
MEYNE, J ;
JOHNSTON, RG ;
CRAM, LS .
CYTOMETRY, 1989, 10 (02) :124-133
[5]   FLUORESCENCE ACTIVATED CELL SORTING [J].
BONNER, WA ;
SWEET, RG ;
HULETT, HR ;
HERZENBERG, LA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1972, 43 (03) :404-+
[6]  
CRAM LS, 1980, FLOW CYTOMETRY, V4, P256
[7]  
CRAM S, 1985, FLOW CYTOMETRY INSTR, P163
[8]   MODULAR ELECTRONICS FOR FLOW-CYTOMETRY AND SORTING - THE LACEL SYSTEM [J].
HIEBERT, RD ;
JETT, JH ;
SALZMAN, GC .
CYTOMETRY, 1981, 1 (05) :337-341
[9]  
HSU TC, 1964, J NATL CANCER I, V321, P857
[10]   SLIT-SCAN FLOW CYTOMETER FOR RECORDING SIMULTANEOUS WAVEFORMS [J].
JOHNSTON, RG ;
BARTHOLDI, MF ;
HIEBERT, RD ;
PARSON, JD ;
CRAM, LS .