FACTORS INFLUENCING THE ACCURACY OF EARLY-PREGNANCY DETECTION IN CATTLE BY REAL-TIME ULTRASOUND SCANNING OF THE UTERUS

被引:32
作者
BADTRAM, GA
GAINES, JD
THOMAS, CB
BOSU, WTK
机构
[1] Department of Medical Sciences School, Veterinary Medicine University of Wisconsin-Madison, Madison
关键词
PREGNANCY DIAGNOSIS; ULTRASOUND; BOVINE;
D O I
10.1016/0093-691X(91)90362-H
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Transrectal real-time ultrasound scanning (5MHz linear array probe) examinations of the uterus were conducted to determine the accuracy of detecting pregnancy and nonpregnancy in 200 Holstein cows and heifers at 16 to 31 d following artificial insemination under field conditions. Two operators separately conducted the examinations. Overall diagnostic accuracy was 62.5%, with a sensitivity of 55.6%, specificity of 70.2%, and a positive predictive value of 67.8%. Diagnostic accuracy and sensitivity were lower (P < 0.05) for examinations performed early (16 to 22 d) than those performed at a later stage (23 to 31 d) after insemination. Diagnostic accuracy and sensitivity of the ultrasound examinations between Days 16 and 22 were 50.0 and 25.0%, respectively, and 70.2 and 68.8%, respectively, between Days 23 and 31. Between operators, no difference was noted in diagnostic accuracy, sensitivity, specificity, or predictive value. However, the sensitivity of one operator decreased slightly when his results were evaluated over three time periods. Results for the heifers examined were not different from those for the cows (P > 0.05) Determination of pregnancy and nonpregnancy, using ultrasound scanning examinations between Days 16 and 31 days postinsemination proved to be significantly less accurate than using palpation per rectum after Day 35 postinsemination. Palpation proved to be 99% accurate in diagnosing pregnancy when compared with breeding and calving records.
引用
收藏
页码:1153 / 1167
页数:15
相关论文
共 15 条
[1]   USE OF A HIGH-FREQUENCY TRANSDUCER WITH REAL-TIME B-MODE ULTRASOUND SCANNING TO IDENTIFY EARLY-PREGNANCY IN COWS [J].
BOYD, JS ;
OMRAN, SN ;
AYLIFFE, TR .
VETERINARY RECORD, 1988, 123 (01) :8-11
[2]  
BULMAN DC, 1979, BRIT VET J, V135, P559
[3]   TRANS-RECTAL REAL-TIME ULTRASOUND SCANNING FOR DIAGNOSING PREGNANCY AND FOR MONITORING EMBRYONIC MORTALITY IN DAIRY-CATTLE [J].
CHAFFAUX, S ;
REDDY, GNS ;
VALON, F ;
THIBIER, M .
ANIMAL REPRODUCTION SCIENCE, 1986, 10 (03) :193-200
[4]  
CURRAN S, 1986, J AM VET MED ASSOC, V189, P1289
[5]  
DUCKER MJ, 1985, BRIT VET J, V141, P515, DOI 10.1016/0007-1935(85)90047-8
[6]   THE USE OF ULTRASONOGRAPHY FOR THE STUDY OF THE BOVINE REPRODUCTIVE-TRACT .2. NONPREGNANT, PREGNANT AND PATHOLOGICAL CONDITIONS OF THE UTERUS [J].
FISSORE, RA ;
EDMONDSON, AJ ;
PASHEN, RL ;
BONDURANT, RH .
ANIMAL REPRODUCTION SCIENCE, 1986, 12 (03) :167-177
[7]   USE OF TRANS-RECTAL B-MODE ULTRASOUND IMAGING IN BOVINE PREGNANCY DIAGNOSIS [J].
HANZEN, C ;
DELSAUX, B .
VETERINARY RECORD, 1987, 121 (09) :200-202
[8]   PRACTICAL USES OF ULTRASOUND IN EARLY-PREGNANCY IN CATTLE [J].
HUGHES, EA ;
DAVIES, DAR .
VETERINARY RECORD, 1989, 124 (17) :456-458
[9]   ACCURACY OF ULTRASONOGRAPHY FOR PREGNANCY DIAGNOSIS ON DAYS 10 TO 22 IN HEIFERS [J].
KASTELIC, JP ;
CURRAN, S ;
GINTHER, OJ .
THERIOGENOLOGY, 1989, 31 (04) :813-820
[10]   ULTRASONIC EVALUATION OF THE BOVINE CONCEPTUS [J].
KASTELIC, JP ;
CURRAN, S ;
PIERSON, RA ;
GINTHER, OJ .
THERIOGENOLOGY, 1988, 29 (01) :39-54