IMPROVED TIME-OF-FLIGHT MR ANGIOGRAPHY OF THE BRAIN WITH MAGNETIZATION TRANSFER CONTRAST

被引:162
作者
EDELMAN, RR [1 ]
AHN, SS [1 ]
CHIEN, D [1 ]
WEI, L [1 ]
GOLDMANN, A [1 ]
MANTELLO, M [1 ]
KRAMER, J [1 ]
KLEEFIELD, J [1 ]
机构
[1] HARVARD UNIV,SCH MED,BOSTON,MA 02115
关键词
BLOOD VESSELS; MR; BRAIN; CEREBRAL BLOOD VESSELS; MAGNETIC RESONANCE (MR); CONTRAST ENHANCEMENT; MAGNETIZATION TRANSFER CONTRAST; VASCULAR STUDIES;
D O I
10.1148/radiology.184.2.1620835
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors hypothesized that magnetization transfer contrast (MTC) could be used to improve flow contrast in time-of-flight (TOF) magnetic resonance (MR) angiography. Two- and three-dimensional flow-compensated gradient-echo images were obtained with and without MTC. MTC images were obtained by applying low-power radio-frequency (RF) radiation with a frequency offset from the bulk "free" water resonance frequency before the excitation RF pulse. The signal intensity of stationary tissue decreased as the power applied for the MTC pulse was increased. A smaller decrease occurred in venous signal intensity as measured in the superior sagittal sinus, and less change was seen in the arterial signal intensity as measured in the middle cerebral artery. Cerebrospinal fluid showed no MTC effect. The use of MTC improved small-vessel depiction on maximum-intensity projection images. The authors conclude that use of MTC can substantially enhance the quality of TOF MR angiography of the brain.
引用
收藏
页码:395 / 399
页数:5
相关论文
共 10 条
[1]   ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS [J].
ANDERSON, CM ;
SALONER, D ;
TSURUDA, JS ;
SHAPEERO, LG ;
LEE, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) :623-629
[2]   MAGNETIZATION TRANSFER CONTRAST IN MR IMAGING OF THE HEART [J].
BALABAN, RS ;
CHESNICK, S ;
HEDGES, K ;
SAMAHA, F ;
HEINEMAN, FW .
RADIOLOGY, 1991, 180 (03) :671-675
[3]   THE APPEARANCE OF RAPIDLY FLOWING BLOOD ON MAGNETIC-RESONANCE IMAGES [J].
BRADLEY, WG ;
WALUCH, V ;
LAI, KS ;
FERNANDEZ, EJ ;
SPALTER, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1167-1174
[4]   PROJECTION ARTERIOGRAPHY AND VENOGRAPHY - INITIAL CLINICAL-RESULTS WITH MR [J].
EDELMAN, RR ;
WENTZ, KU ;
MATTLE, H ;
ZHAO, B ;
LIU, C ;
KIM, D ;
LAUB, G .
RADIOLOGY, 1989, 172 (02) :351-357
[5]   FAST TIME-OF-FLIGHT MR-ANGIOGRAPHY WITH IMPROVED BACKGROUND SUPPRESSION [J].
EDELMAN, RR ;
CHIEN, D ;
ATKINSON, DJ ;
SANDSTROM, J .
RADIOLOGY, 1991, 179 (03) :867-870
[6]   MR ANGIOGRAPHY WITH GRADIENT MOTION REFOCUSING [J].
LAUB, GA ;
KAISER, WA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (03) :377-382
[7]   INTRACRANIAL CIRCULATION - PULSE-SEQUENCE CONSIDERATIONS IN 3-DIMENSIONAL (VOLUME) MR ANGIOGRAPHY [J].
RUGGIERI, PM ;
LAUB, GA ;
MASARYK, TJ ;
MODIC, MT .
RADIOLOGY, 1989, 171 (03) :785-791
[8]   MAGNETIZATION TRANSFER CONTRAST - METHOD FOR IMPROVING CONTRAST IN GRADIENT-RECALLED-ECHO IMAGES [J].
WOLFF, SD ;
ENG, J ;
BALABAN, RS .
RADIOLOGY, 1991, 179 (01) :133-137
[9]   MAGNETIZATION TRANSFER CONTRAST - MR-IMAGING OF THE KNEE [J].
WOLFF, SD ;
CHESNICK, S ;
FRANK, JA ;
LIM, KO ;
BALABAN, RS .
RADIOLOGY, 1991, 179 (03) :623-628
[10]   MAGNETIZATION TRANSFER CONTRAST (MTC) AND TISSUE WATER PROTON RELAXATION INVIVO [J].
WOLFF, SD ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1989, 10 (01) :135-144