DOSIMETRY CHARACTERISTICS OF METALLIC CONES FOR INTRAOPERATIVE RADIOTHERAPY

被引:13
作者
NYERICK, CE
OCHRAN, TG
BOYER, AL
HOGSTROM, KR
机构
[1] Department of Radiation Physics, The University of Texas, M. D. Anderson Cancer Center, Houston, TX 77030
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1991年 / 21卷 / 02期
关键词
INTRAOPERATIVE RADIOTHERAPY; ELECTRON DOSIMETRY; ELECTRON CONES; LINEAR ACCELERATORS;
D O I
10.1016/0360-3016(91)90802-B
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Dosimetry data were obtained on the first dedicated linear accelerator of its type designed for electron intraoperative radiotherapy (IORT) within an operating room. The linear accelerator uses a high dose rate, 9 Gy.min-1, to reduce the treatment time. Its chrome-plated brass treatment cones, designed with straight ends and 22.5-degrees beveled ends, are not mechanically attached to the collimator head, but are aligned using a laser projection system. Dosimetry measurements were made for each combination of energy (6, 9, 12, 15, and 16 MeV), cone size (diameters range from 5 to 12 cm), and cone type (22.5-degrees beveled or straight). From these data, depth-dose curves, cone output, and air-gap correction factors were generated that allow the calculation of the monitor setting for delivering a prescribed dose at any depth for any irradiation condition (energy, cone, air gap). Isodose data were measured for every cone using film in a solid water phantom. Scatter off the inside wall of the cone resulted in peripheral dose horns near the surface that were energy and cone dependent, being as large as 120%.
引用
收藏
页码:501 / 510
页数:10
相关论文
共 21 条
[1]  
ALMOND PR, 1976, CLIN APPLICATIONS EL, P7
[2]  
[Anonymous], 1983, MED PHYS, V10, P741
[3]   RADIATION CONTAMINATION AND LEAKAGE ASSESSMENT OF INTRAOPERATIVE ELECTRON APPLICATORS [J].
BAGNE, FR ;
SAMSAMI, N ;
DOBELBOWER, RR .
MEDICAL PHYSICS, 1988, 15 (04) :530-537
[4]   DOSIMETRY, FIELD SHAPING AND OTHER CONSIDERATIONS FOR INTRAOPERATIVE ELECTRON THERAPY [J].
BIGGS, PJ ;
EPP, ER ;
LING, CC ;
NOVACK, DH ;
MICHAELS, HB .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (07) :875-884
[5]  
BOYER A, 1988, 1987 P THER US C SIE, P27
[6]   DETERMINATION OF ACCURATE DOSIMETRIC PARAMETERS FOR BEVELED INTRAOPERATIVE ELECTRON-BEAM APPLICATORS [J].
DAHL, RA ;
MCCULLOUGH, EC .
MEDICAL PHYSICS, 1989, 16 (01) :130-131
[7]   THE PROBLEM OF OBLIQUELY INCIDENT BEAMS IN ELECTRON-BEAM TREATMENT PLANNING [J].
EKSTRAND, KE ;
DIXON, RL .
MEDICAL PHYSICS, 1982, 9 (02) :276-278
[8]   INTRAOPERATIVE RADIATION-THERAPY AT THE NATIONAL-CANCER-INSTITUTE - TECHNICAL INNOVATIONS AND DOSIMETRY [J].
FRAASS, BA ;
MILLER, RW ;
KINSELLA, TJ ;
SINDELAR, WF ;
HARRINGTON, FS ;
YEAKEL, K ;
VANDEGEIJN, J ;
GLATSTEIN, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (07) :1299-1311
[9]   DESIGN OF METALLIC ELECTRON-BEAM CONES FOR AN INTRAOPERATIVE THERAPY LINEAR-ACCELERATOR [J].
HOGSTROM, KR ;
BOYER, AL ;
SHIU, AS ;
OCHRAN, TG ;
KIRSNER, SM ;
KRISPEL, F ;
RICH, T .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (05) :1223-1232
[10]  
HOGSTROM KR, 1982, MED PHYS, V9, P611