RADIOGRAPHIC DIAGNOSIS OF BREAST IMPLANT RUPTURE - CURRENT STATUS AND COMPARISON OF TECHNIQUES

被引:31
作者
SAMUELS, JB
ROHRICH, RJ
WEATHERALL, PT
HO, AMW
GOLDBERG, KL
机构
[1] UNIV TEXAS, SOUTHWESTERN MED CTR, DIV PLAST & RECONSTRUCT SURG, DALLAS, TX 75235 USA
[2] UNIV TEXAS, SOUTHWESTERN MED CTR, DEPT RADIOL, DALLAS, TX 75235 USA
关键词
D O I
10.1097/00006534-199509001-00016
中图分类号
R61 [外科手术学];
学科分类号
摘要
Rupture of a breast implant is a recognized complication of augmentation mammaplasty and reconstructive breast surgery. Due to concerns over the extravasation of silicone gel within adjacent tissue and distant body sites, considerable attention has been given to the radiographic detection of mammary implant rupture. A metaanalysis comparing the accuracy of various currently available imaging modalities tvas conducted and an algorithm suggested to guide clinicians in the detection of breast implant rupture. Advantages and limitations of mammography, xeromammography, ultrasonography, MRI, and CT are outlined as well as some of the most specific radiographic signs of each with illustrative examples from patients evaluated at our institution. Results of our retrospective analysis corroborated by a review of the most recent literature reveal that mammography supplemented with ultrasonography constitutes the most cost-effective initial study, followed by MRI if these are equivocal. MRI is the most sensitive and specific study to evaluate breast implant rupture.
引用
收藏
页码:865 / 877
页数:13
相关论文
共 40 条
[1]   THE DIAGNOSIS OF RUPTURED BREAST IMPLANTS [J].
ANDERSEN, B ;
HAWTOF, D ;
ALANI, H ;
KAPETANSKY, D .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 84 (06) :903-907
[2]  
BERG WA, IN PRESS RADIOGRAPHI
[3]  
BREM RF, 1992, J COMPUT ASSIST TOMO, V16, P157
[4]   ULTRASOUND MAMMOGRAPHY FOR THE AUGMENTED BREAST [J].
COLEBEUGLET, C ;
SCHWARTZ, G ;
KURTZ, AB ;
PATCHEFSKY, AS ;
GOLDBERG, BB .
RADIOLOGY, 1983, 146 (03) :737-742
[5]   MAMMOGRAPHY IN THE 80S [J].
CONWAY, BJ ;
MCCROHAN, JL ;
RUETER, FG ;
SULEIMAN, OH .
RADIOLOGY, 1990, 177 (02) :335-339
[6]  
DEANGELIS GA, IN PRESS RADIOGRAPHI
[7]  
DELANGE EE, 1992, RADIOLOGY, V185, P378
[8]   RUPTURE OF A SILICONE BAG-GEL BREAST IMPLANT BY CLOSED COMPRESSION CAPSULOTOMY [J].
EISENBERG, HV ;
BARTELS, RJ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1977, 59 (06) :849-850
[9]   IMPROVED IMAGING OF THE AUGMENTED BREAST [J].
EKLUND, GW ;
BUSBY, RC ;
MILLER, SH ;
JOB, JS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (03) :469-473
[10]   RUPTURE OF INFLATED BREAST IMPLANTS IN CLOSE COMPRESSION CAPSULOTOMY [J].
FELIBERTI, MC ;
ARRILLAGA, A ;
COLON, GA .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1977, 59 (06) :848-848