TUMOR-TISSUE OXYGENATION AS EVALUATED BY COMPUTERIZED-PO2-HISTOGRAPHY

被引:229
作者
KALLINOWSKI, F
ZANDER, R
HOECKEL, M
VAUPEL, P
机构
[1] HARVARD UNIV,MASSACHUSETTS GEN HOSP,SCH MED,DEPT RADIAT MED,BOSTON,MA 02114
[2] UNIV MAINZ,INST PHYSIOL & PATHOPHYSIOL,W-6500 MAINZ,GERMANY
[3] UNIV MAINZ,DEPT GYNECOL & OBSTET,W-6500 MAINZ,GERMANY
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1990年 / 19卷 / 04期
关键词
Human tumor xenografts; Oxygen partial pressure distribution; Oxygen tension; pO[!sub]2[!/sub] electrode; pO[!sub]2[!/sub] histograms; Primary human tumors; Rodent tumors;
D O I
10.1016/0360-3016(90)90018-F
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A computerized pO2 measurement system with a novel electrode motion pattern (Sigma-pO2-histography) was evaluated in vitro and in vivo. The system was found to be reliable in 0.9% saline and 10% hydroxyethylene starch solution and in fresh donor blood. Marked deviations were found in lipid and hemoglobin solutions and in fluorocarbon emulsions. Histograms obtained in rat liver, mouse muscle, and subcutis were similar to previously reported distributions. Direct comparison between Sigma-Eppendorf and self-constructed Whalen-type electrodes in hypoxic tumors gave similar results. A large series of measurements indicated that hypoxic and anoxic tissue areas were frequently found both in isografted rodent and in xenografted human tumors. The extent of oxygen deprivation depended on the cell line studied, tumor size, implantation site, the vascularity, and the actual tissue perfusion. Pentobarbital anesthesia redistributed the tumor oxygenation without affecting the median pO2 value. Tumors growing in a pre-irradiated bed were less oxygenated than those at untreated sites. Hyperthermia at therapeutically relevant temperatures reduced pO2 levels in adequately oxygenated tumors whereas little change was detected in poorly oxygenated tumors. First measurements in tumors in patients revealed marked inter- and intratumor heterogeneity. It is concluded that this novel technique is suitable for routine measurements of tissue oxygenation of solid tumors in situ. © 1990.
引用
收藏
页码:953 / 961
页数:9
相关论文
共 36 条
  • [1] Baumgartl H, 1983, POLAROGRAPHIC OXYGEN, P37, DOI [10.1007/978-3-642-81863-9_4, DOI 10.1007/978-3-642-81863-9_4]
  • [3] Fleckenstein W, 1984, FOCUS MHL, V1, P74
  • [4] FORTMEYER HP, 1981, THYMUSAPLASTIC NUDE, P25
  • [5] OXYGEN DISTRIBUTION IN SQUAMOUS-CELL CARCINOMA METASTASES AND ITS RELATIONSHIP TO OUTCOME OF RADIATION-THERAPY
    GATENBY, RA
    KESSLER, HB
    ROSENBLUM, JS
    COIA, LR
    MOLDOFSKY, PJ
    HARTZ, WH
    BRODER, GJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (05): : 831 - 838
  • [6] DIFFUSION ERROR AND O2 CONSUMPTION OF PT ELECTRODE DURING PO2 MEASUREMENTS IN STEADY STATE
    GRUNEWALD, W
    [J]. PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1970, 320 (01): : 24 - +
  • [7] GULLINO PM, CANCER, V3, P327
  • [8] INCREASE IN TUMOR PO2 BY PERFLUOROCHEMICALS AND CARBOGEN
    HASEGAWA, T
    RHEE, JG
    LEVITT, SH
    SONG, CW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (04): : 569 - 574
  • [9] JAIN RK, 1988, CANCER RES, V48, P2641
  • [10] EFFECT OF X-IRRADIATION OF TUMOR BED ON TUMOR BLOOD-FLOW AND VASCULAR-RESPONSE TO DRUGS
    JIRTLE, R
    RANKIN, JHG
    CLIFTON, KH
    [J]. BRITISH JOURNAL OF CANCER, 1978, 37 (06) : 1033 - 1038