USE OF CAPILLARY SUCTION APPARATUS FOR ESTIMATING THE AVERAGED SPECIFIC RESISTANCE OF FILTRATION CAKE

被引:37
作者
LEE, DJ [1 ]
HSU, YH [1 ]
机构
[1] YUAN ZE INST TECHNOL,DEPT CHEM ENGN,TAYUAN 32026,TAIWAN
关键词
CAPILLARY SUCTION APPARATUS; DIFFUSION-LIKE APPROACH; CAKE FORMATION; SPECIFIC RESISTANCE;
D O I
10.1002/jctb.280590108
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A method for estimating the averaged specific resistance of filtration cake, which avoids the necessity of measuring the liquid invasion volume in capillary suction apparatus (CSA) experiments, is proposed. When insufficient slurry is used, the slurry will exhaust during an experiment and the curve of wet front radius versus time shows transition. The transition point shifts according to the slurry concentration, cake specific resistance and the CSA parameters. Based on the wet front radius and the capillary suction time (CST) of the transition point, the liquid saturation under the inner cylinder can be estimated and the averaged specific resistance of cake calculated without the liquid invasion volume data. The proposed method agrees well with vacuum filtration data.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 19 条
[1]  
Baskerville RC., 1968, WATER POLLUT CONTROL, V67, P233
[2]  
CHANG LS, 1988, SOC PHOTOGRAPHIC SCI
[3]   INTERPRETATION OF DE-WATERABILITY MEASUREMENTS BY CAPILLARY SUCTION TIME (CST) [J].
DOHANYOS, M ;
GRAU, P ;
SEDLACEK, M .
WATER SCIENCE AND TECHNOLOGY, 1988, 20 (01) :265-267
[4]  
GALE RS, 1970, FILTRN SEPARN, V7, P37
[5]  
GALE RS, 1967, CHEM IND, V9, P355
[6]  
HAYASHI N, 1990, INT CHEM ENG, V30, P691
[7]  
JU SC, 1982, THESIS NATIONAL TAIW
[8]  
KARR PR, 1978, J WATER POLLUT CON F, V50, P1911
[9]   EFFECTS OF SONICATION ON ACTIVATED-SLUDGE [J].
KING, RO ;
FORSTER, CF .
ENZYME AND MICROBIAL TECHNOLOGY, 1990, 12 (02) :109-115
[10]   CAPILLARY SORPTION IN FIBROUS ASSEMBLIES [J].
KISSA, E .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1981, 83 (01) :265-272