DETECTION OF GLAUCOMATOUS DAMAGE IN PATIENTS WITH OSTEO-ODONTOKERATOPROSTHESIS

被引:24
作者
FALCINELLI, GC [1 ]
FALSINI, B [1 ]
TALONI, M [1 ]
PICCARDI, M [1 ]
FALCINELLI, G [1 ]
机构
[1] S CAMILLO GEN HOSP,DEPT OPHTHALMOL,ROME,ITALY
关键词
D O I
10.1136/bjo.79.2.129
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background-Osteo-odontokeratoprosthesis (OOKP) is an autologous transplantation procedure in which the cornea is replaced by an optical cylinder glued to a biological support. Patients undergoing OOKP surgery may develop a secondary glaucoma whose diagnosis, by means of standard diagnostic procedures, is often doubtful. Methods-In the present study pattern electroretinograms (PERGs), visual evoked potentials (VEPs), contrast sensitivity, and automated threshold perimetry (Humphrey 30-2) were evaluated in 19 OOKP treated patients with postoperative visual acuities greater than or equal to 0.8. Nine patients had had a preoperative secondary glaucoma, while the remaining 10 had no history of glaucoma and normal posterior pole. Results-Results were compared with those obtained from either normal control subjects or from ordinary glaucoma patients. PERG amplitudes and contrast and perimetric sensitivities were reduced in both groups of OOKP patients when compared with normal controls. However, these losses were significantly greater in OOKP patients with glaucoma compared with those with normal posterior pole. VEPs were reduced, compared with controls, only in OOKP patients with glaucoma. These VEP losses were similar to those found in ordinary glaucoma patients. Conclusion-Among the tests employed, VEPs showed the best accuracy (79%) in discriminating between glaucomatous and non-glaucomatous OOKP treated eyes. The present results suggest a possible use of the VEP technique for detecting glaucomatous dysfunction after OOKP.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 17 条
[1]  
BODISWOLLNER I, 1989, SURV OPHTHALMOL, V33, P301
[2]  
FALCINELLI G, 1987, 25 ACT CONC OPHTH, V2, P2772
[3]  
Falcinelli G, 1993, REFRACT CORNEAL SURG, P193
[4]  
KLEIN BEK, 1985, OPHTHALMOLOGY, V92, P1654
[5]  
LUSTGARTEN JS, 1990, CLIN VISION SCI, V4, P407
[6]  
MANNOR MF, 1989, ARCH OPHTHALMOL-CHIC, V107, P816
[7]   SIGNS OF EARLY DAMAGE IN GLAUCOMATOUS MONKEY EYES - LOW SPATIAL-FREQUENCY LOSSES IN THE PATTERN ERG AND VEP [J].
MARX, MS ;
PODOS, SM ;
BODISWOLLNER, I ;
LEE, PY ;
WANG, RF ;
SEVERIN, C .
EXPERIMENTAL EYE RESEARCH, 1988, 46 (02) :173-184
[8]   THE PATTERN EVOKED ELECTRORETINOGRAM IN OPTIC NEURITIS - A COMBINED PSYCHOPHYSICAL AND ELECTROPHYSIOLOGICAL STUDY [J].
PLANT, GT ;
HESS, RF ;
THOMAS, SJ .
BRAIN, 1986, 109 :469-489
[9]   PATTERN ELECTRORETINOGRAM AS A FUNCTION OF SPATIAL-FREQUENCY IN OCULAR HYPERTENSION AND EARLY GLAUCOMA [J].
PORCIATTI, V ;
FALSINI, B ;
BRUNORI, S ;
COLOTTO, A ;
MORETTI, G .
DOCUMENTA OPHTHALMOLOGICA, 1987, 65 (03) :349-355
[10]   STRAMPELLI OSTEO-ODONTO-KERATOPROSTHESIS - CLINICAL AND HISTOLOGICAL LONG-TERM FEATURES OF 3 PROSTHESES [J].
RICCI, R ;
PECORELLA, I ;
DELLAROCCA, C ;
DITONDO, U ;
MARCHI, V .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1992, 76 (04) :232-234