VOLUMETRIC FLOW-RATES IN THE PORTAL VENOUS SYSTEM - MEASUREMENT WITH CINE PHASE-CONTRAST MR IMAGING

被引:59
作者
BURKART, DJ [1 ]
JOHNSON, CD [1 ]
MORTON, MJ [1 ]
WOLF, RL [1 ]
EHMAN, RL [1 ]
机构
[1] MAYO CLIN & MAYO FDN, DEPT DIAGNOST RADIOL, 200 1ST ST SW, ROCHESTER, MN 55905 USA
关键词
D O I
10.2214/ajr.160.5.8470589
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purposes of this study were to (1) validate the accuracy of cine phase-contrast MR flow measurements within the portal vein, (2) develop a suitable protocol for using this method to measure volumetric flow rate in the portal venous system, and (3) use this protocol, with Doppler sonography as a reference, to measure portal venous flow in healthy volunteers and in patients with portal venous hypertension. SUBJECTS AND METHODS. Flow determinations were obtained in a model of fluid movement approximating blood-flow conditions in the portal venous system. A suitable protocol was based on consideration of the theoretical effects of (1) spatial resolution, (2) obliquity of the imaging plane to the direction of flow, and (3) signal-to-noise ratio of the signed quantitative velocity images (in three volunteers) on the accuracy and precision of flow measurements. This protocol was used to obtain cine phase-contrast MR images of the portal venous system in five volunteers and six patients. RESULTS. Values obtained with a flow phantom showed good accuracy of cine phase-contrast-measured vs actual volumetric flow rate (r= .995; p= .0001; MR rate = [0.94 x actual rate] + 65.6 ml/min; standard error of the y estimate = 67.3 ml/min). Velocity encoding and section thickness substantially influenced the signal-to-noise ratio of the velocity images, whereas flip angle and matrix size had only minimal effect. In volunteers and patients, portal volumetric flow rates determined by using MR images and Doppler sonography showed good correlation (r= .94; p = .0003). CONCLUSION. Our results indicate that cine phase-contrast MR imaging is a practical noninvasive method for measuring volumetric flow rates in the portal venous system.
引用
收藏
页码:1113 / 1118
页数:6
相关论文
共 21 条
  • [1] BLOOD-FLOW EFFECTS IN MAGNETIC-RESONANCE IMAGING
    AXEL, L
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) : 1157 - 1166
  • [2] SONOGRAPHY OF THE HEPATIC VASCULAR SYSTEM
    BECKER, CD
    COOPERBERG, PL
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (05) : 999 - 1005
  • [3] BURNS PN, 1985, RADIOL CLIN N AM, V23, P641
  • [4] MR ANGIOGRAPHY AND DYNAMIC FLOW EVALUATION OF THE PORTAL VENOUS SYSTEM
    EDELMAN, RR
    ZHAO, B
    LIU, C
    WENTZ, KU
    MATTLE, HP
    FINN, JP
    MCARDLE, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (04) : 755 - 760
  • [5] EFFECT OF PROPRANOLOL ON PORTOSYSTEMIC COLLATERAL CIRCULATION IN PATIENTS WITH CIRRHOSIS
    GAIANI, S
    BOLONDI, L
    FENYVES, D
    ZIRONI, G
    RIGAMONTI, A
    BARBARA, L
    [J]. HEPATOLOGY, 1991, 14 (05) : 824 - 829
  • [6] DETECTION OF SEA-WATER MOTION BY NUCLEAR PRECESSION
    HAHN, EL
    [J]. JOURNAL OF GEOPHYSICAL RESEARCH, 1960, 65 (02): : 776 - 777
  • [7] T1-WEIGHTED SNAPSHOT GRADIENT-ECHO MR IMAGING OF THE ABDOMEN
    HOLSINGERBAMPTON, AE
    RIEDERER, SJ
    CAMPEAU, NG
    EHMAN, RL
    JOHNSON, CD
    [J]. RADIOLOGY, 1991, 181 (01) : 25 - 32
  • [8] RIGHT AND LEFT-VENTRICULAR STROKE VOLUME MEASUREMENTS WITH VELOCITY-ENCODED CINE MR IMAGING - INVITRO AND INVIVO VALIDATION
    KONDO, C
    CAPUTO, GR
    SEMELKA, R
    FOSTER, E
    SHIMAKAWA, A
    HIGGINS, CB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) : 9 - 16
  • [9] LFUBICIC N, 1991, SCAND J GASTROENTERO, V26, P751
  • [10] VENA-CAVAL FLOW - ASSESSMENT WITH CINE MR VELOCITY MAPPING
    MOHIADDIN, RH
    WANN, SL
    UNDERWOOD, R
    FIRMIN, DN
    REES, S
    LONGMORE, DB
    [J]. RADIOLOGY, 1990, 177 (02) : 537 - 541