THERMAL-STRESS COMPUTATION FOR STEAM-ELECTRIC GENERATOR DISPATCH

被引:4
作者
DELSON, JK
机构
[1] Applied Analytics Associates, Palo Alto, California
关键词
DYNAMIC DISPATCH; FATIGUE INDEX; GENERATOR OPERATING CONSTRAINTS; POWER GENERATION DISPATCH; POWER SYSTEM OPERATION; RAMP RATES;
D O I
10.1109/59.317550
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Calculation of thermal stress in loading and unloading steam-electric generators can permit dispatch at higher ramp rates without increasing turbine rotor fatigue. The calculations are made from a thermal model of the rotor that does not require temperature sensors. The equations are validated against the fatigue index curves provided by turbine manufacturers. Examples are presented to show the advantage of using this model for dispatch and for the retrospective analysis of power output records.
引用
收藏
页码:120 / 126
页数:7
相关论文
共 9 条
[1]  
CLELLAND PJ, 1982, EL2461 EL POW RES I
[2]  
DELSON JK, 1992, ASME PWR PUBLICATION, V18
[3]  
JONES JA, 1988, CSES5593 EL POW RES
[4]  
MARSHALL GW, 1983, 1983 SE EL EXCH ANN
[5]  
MARTIN HF, 1984, CS3800 EL POW RES I
[6]   TURBINE CONTROL-SYSTEM BASED ON PREDICTION OF ROTOR THERMAL-STRESS [J].
MATSUMOTO, H ;
SATO, Y ;
KATO, F ;
EKI, Y ;
HISANO, K ;
FUKUSHIMA, K .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (08) :2504-2512
[7]  
SPRINGER SL, 1988, ASME PWR, V3, P161
[8]  
TAVERNELLI JF, 1962, ASME D, P533
[9]  
TIMO DP, ASME82T11 PAP