AUTOMATED-DETERMINATION OF CROSS-LINKED FIBRIN DERIVATIVES IN PLASMA

被引:11
作者
ELMS, MJ
BUNDESEN, PG
ROWBURY, D
GOODALL, S
WAKEHAM, N
ROWELL, JA
HILLYARD, CJ
RYLATT, DB
机构
[1] ROYAL BRISBANE HOSP,DEPT PATHOL,BRISBANE,QLD 4029,AUSTRALIA
[2] AGEN BIOMED LTD,BRISBANE,AUSTRALIA
关键词
ASSAY METHODS; AUTOMATED DETERMINATION; FIBRIN DERIVATIVES; D-DIMER; XL-FBDP;
D O I
10.1097/00001721-199304010-00028
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Automated assays for the measurement of cross-linked fibrin derivatives in plasma (XL-FbDP) have been developed utilizing latex beads coated with anti-D dimer monoclonal antibody (DD-3B6/22) for both the Cobas Fara Chemistry Centrifugal and the Cobas Mira analysers (Roche, Basle, Switzerland). The analysers were programmed to mix plasma and latex reagent simultaneously and analyse absorbance changes over a 10-15 min period. Results were interpolated by the analyser from a standard curve derived from a polymer of D-dimer. Both assays had high precision (< 5% CV) for values between 100 and 1 000 ng/ml and provided clear discrimination between normal samples and samples from patients suffering from the thrombotic diseases, DVT/PE and DIC. The results obtained for XL-FbDP determination with both methods compared well with established methods: a high correlation was obtained with a semi-quantitative manual latex method for both the Fara (r = 0.92) and Mira (r = 0.83) and correlations (r) of 0.81 (Fara) and 0.84 (Mira) were obtained with an enzyme immunoassay (EIA). Correlation between the two automated procedures was high (r = 0.96). The automated method will enable laboratories to provide a rapid and accurate quantitation of XL-FbDP.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 14 条
[1]  
DECLERCK PJ, 1987, THROMB HAEMOSTASIS, V58, P1024
[2]   VALIDITY OF ENZYME-LINKED IMMUNOSORBENT ASSAYS OF CROSS-LINKED FIBRIN DEGRADATION PRODUCTS AS A MEASURE OF CLOT LYSIS [J].
EISENBERG, PR ;
JAFFE, AS ;
STUMP, DC ;
COLLEN, D ;
BOVILL, EG .
CIRCULATION, 1990, 82 (04) :1159-1168
[3]  
ELMS MJ, 1983, THROMB HAEMOSTASIS, V50, P591
[4]   MONOCLONAL-ANTIBODIES TO CROSSLINKED FIBRIN DEGRADATION PRODUCTS (XL-FDP) .1. CHARACTERIZATION AND PRELIMINARY EVALUATION IN PLASMA [J].
GAFFNEY, PJ ;
CREIGHTON, LJ ;
PERRY, MJ ;
CALLUS, M ;
THORPE, R ;
SPITZ, M .
BRITISH JOURNAL OF HAEMATOLOGY, 1988, 68 (01) :83-90
[5]   DETECTION AND RELEVANCE OF CROSSLINKED FIBRIN DERIVATIVES IN BLOOD [J].
GRAEFF, H ;
HAFTER, R .
SEMINARS IN THROMBOSIS AND HEMOSTASIS, 1982, 8 (01) :57-68
[6]  
HILLYARD CJ, 1987, CLIN CHEM, V33, P18837
[7]   THE SIMPLIRED-D DIMER TEST - A NOVEL ASSAY FOR THE DETECTION OF CROSS-LINKED FIBRIN DEGRADATION PRODUCTS IN WHOLE-BLOOD [J].
JOHN, MA ;
ELMS, MJ ;
OREILLY, EJ ;
RYLATT, DB ;
BUNDESEN, PG ;
HILLYARD, CJ .
THROMBOSIS RESEARCH, 1990, 58 (03) :273-281
[8]  
KOPPERT PW, 1988, THROMB HAEMOSTASIS, V59, P310
[9]  
KORNEMAN H, 1990, BLOOD COAG FIRBINOL, V1, P91
[10]   MONOCLONAL-ANTIBODIES TO FIBRINOGEN-FIBRIN DEGRADATION PRODUCTS WHICH CONTAIN D-DOMAIN [J].
MATSUMOTO, T ;
NISHIJIMA, Y ;
TERAMURA, Y ;
FUJINO, K ;
HIBINO, M ;
HIRATA, M .
THROMBOSIS RESEARCH, 1985, 38 (03) :297-302