DUAL KV CT TO DETECT CALCIFICATION IN SOLITARY PULMONARY NODULE

被引:18
作者
BHALLA, M
SHEPARD, JO
NAKAMURA, K
KAZEROONI, EA
机构
[1] Department of Radiology, Massachusetts General Hospital, Boston, MA, 02114
[2] Department of Radiology, University of Michigan, Ann Arbor, MI
关键词
COMPUTED TOMOGRAPHY; TECHNIQUES; LUNGS; NEOPLASMS; ATTENUATION VALUES;
D O I
10.1097/00004728-199501000-00008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: At the high kVp values used in CT scanning, almost all interactions in soft tissues occur by Compton scattering. By lowering the kVp close to the k-edge of calcium, beam attenuation by calcium will be greater and will be reflected as an increase in density reading (DR). The presence of calcification in solitary pulmonary nodules (SPNs), and thus an implied benign etiology, is currently being diagnosed on CT by using reference phantoms. We explored the possibility of utilizing low kVp (i.e., 80 kVp) to detect the presence of such calcification in SPNs, thus obviating the need for expensive and cumbersome reference phantoms. Materials and Methods: We first tested this phenomenon of photoelectric interaction by CT and its effect on DRs by scanning various dilutions of calcium bicarbonate solution at the standard 140 kVp and at a lower, 80 kVp, setting. After confirming the hypothesis, we conducted a prospective clinical study of 27 consecutive SPNs and scanned them at 140 and 80 kVp to detect the presence of calcification by measuring their DRs at both kVp values. Results: All calcium solutions showed an increase in DR on the 80 kVp scan. Of the 27 nodules, 11 (41%) showed an increase in DR, suggesting the presence of calcification: 10 (91%) were benign, and 1 (9%) was malignant. Conclusion: Our study demonstrates that dual kVp CT could be reliably used to identify calcifications in SPNs, very similar to the use of the reference phantoms currently being applied for the purpose.
引用
收藏
页码:44 / 47
页数:4
相关论文
共 16 条
[1]   BREAST IMAGING - DUAL-ENERGY PROJECTION RADIOGRAPHY WITH DIGITAL RADIOGRAPHY [J].
ASAGA, T ;
CHIYASU, S ;
MASTUDA, S ;
MASTUURA, H ;
KATO, H ;
ISHIDA, M ;
KOMAKI, T .
RADIOLOGY, 1987, 164 (03) :869-870
[2]   QUANTITATIVE THEORY OF HOUNSFIELD UNIT AND ITS APPLICATION TO DUAL ENERGY SCANNING [J].
BROOKS, RA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (04) :487-493
[3]   QUANTIFICATION OF CALCIUM IN SOLITARY PULMONARY NODULES USING SINGLE-ENERGY AND DUAL-ENERGY CT [J].
CANN, CE ;
GAMSU, G ;
BIRNBERG, FA ;
WEBB, WR .
RADIOLOGY, 1982, 145 (02) :493-496
[4]   QUANTITATIVE CT APPLICATIONS - COMPARISON OF CURRENT SCANNERS [J].
CANN, CE .
RADIOLOGY, 1987, 162 (01) :257-261
[5]  
CURRY TS, 1984, CHRISTENSENS INTRO P, P60
[6]   TISSUE SIGNATURES WITH DUAL-ENERGY COMPUTED-TOMOGRAPHY [J].
DICHIRO, G ;
BROOKS, RA ;
KESSLER, RM ;
JOHNSTON, GS ;
JONES, AE ;
HERDT, JR ;
SHERIDAN, WT .
RADIOLOGY, 1979, 131 (02) :521-523
[7]  
Friedemberg RM, 1990, CLIN UROGRAPHY, P101
[8]  
HENDEE WR, 1983, PHYSICAL PRINCIPLES, P101
[9]   DUAL-ENERGY DIGITAL RADIOGRAPHIC QUANTIFICATION OF CALCIUM IN SIMULATED PULMONARY NODULES [J].
HICKEY, NM ;
NIKLASON, LT ;
SABBAGH, E ;
FRASER, RG ;
BARNES, GT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (01) :19-24
[10]   CT DEMONSTRATION OF CALCIFICATION IN CARCINOMA OF THE LUNG [J].
MAHONEY, MC ;
SHIPLEY, RT ;
CORCORAN, HL ;
DICKSON, BA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (02) :255-258