EFFECT OF SOLVENT POLARITY ON THE DETERMINATION OF OXO-POLYCYCLIC AND NITRO-POLYCYCLIC AROMATIC-HYDROCARBONS USING CAPILLARY GAS-CHROMATOGRAPHY WITH SPLITLESS INJECTION

被引:13
作者
GALCERAN, MT
MOYANO, E
机构
[1] Department of Analytical Chemistry, University of Barcelona, 08028 Barcelona
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 607卷 / 02期
关键词
D O I
10.1016/0021-9673(92)87087-O
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The importance of solvent polarity in the injection conditions for the determination of oxo- and nitro-polyclic aromatic hydrocarbons in capillary gas chromatography was investigated. When standard solutions Of these compounds were analysed by high-resolution gas chromatography using splitless injection, peak splitting with two or more maxima was obtained when methanol and acetonitrile were used, in the preceding steps no peak splitting was observed with dichloromethane or acetone. This splitting can be eliminated using a retention gap or by increasing the initial column temperature. Response factors for all these compounds at different initial temperatures and different solvents were studied. The best results were obtained using acetonitrile, an initial temperature of 60-degrees-C and a retention gap. Reproducibility gave a relative standard deviation from 1.8 to 6.7 when measured by peak area; detection limits (signal-to-noise ratio of 2:1) using a flame ionization detector ranged from 129 pg for 2-methyl-1-nitronaphthalene to 1.5 ng for 9, 10-phenanthroquinone.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 23 条
[1]  
ANG KP, 1987, INT J ENVIRON STUD, V29, P163
[2]   INVESTIGATION INTO THE FACTORS AFFECTING PERFORMANCE IN THE DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS USING CAPILLARY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY WITH SPLITLESS INJECTION [J].
BRINDLE, ID ;
LI, XF .
JOURNAL OF CHROMATOGRAPHY, 1990, 498 (01) :11-24
[3]   FRACTIONATION OF POLAR POLYNUCLEAR AROMATIC-HYDROCARBONS PRESENT IN INDUSTRIAL EMISSIONS AND ATMOSPHERIC SAMPLES AND THEIR DETERMINATION BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
CICCIOLI, P ;
BRANCALEONI, E ;
CECINATO, A ;
DIPALO, C ;
BUTTINI, P ;
LIBERTI, A .
JOURNAL OF CHROMATOGRAPHY, 1986, 351 (03) :451-464
[4]  
DOLECKA E, 1990, HRC-J HIGH RES CHROM, V13, P405
[5]   ELIMINATION OF PEAK SPLITTING AND DISTORTION ASSOCIATED WITH LIQUID SAMPLE ON-COLUMN INJECTION - SOLVENT POLARITY EFFECTS [J].
GHAOUI, L ;
WANG, FS ;
SHANFIELD, H ;
ZLATKIS, A .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1983, 6 (09) :497-500
[6]  
GROB K, 1974, J CHROMATOGR, V94, P53
[7]   PEAK BROADENING OR SPLITTING CAUSED BY SOLVENT FLOODING AFTER SPLITLESS OR COLD ON-COLUMN INJECTION IN CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1981, 213 (01) :3-14
[8]   SPLITLESS INJECTION ON CAPILLARY COLUMNS, .I. BASIC TECHNIUE - STEROID ANALYSIS AS AN EXAMPLE [J].
GROB, K ;
GROB, G .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1969, 7 (10) :584-&
[9]   ON-COLUMN INJECTION ON TO GLASS CAPILLARY COLUMNS [J].
GROB, K ;
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1978, 151 (03) :311-320
[10]  
GROB K, 1991, HRC-J HIGH RES CHROM, V14, P212