SIGNAL STANDARDIZATION OF THE SECONDARY-ION MASS-SPECTROMETRY (SIMS) MICROSCOPE FOR QUANTIFICATION OF HALOGENS AND CALCIUM IN BIOLOGICAL APPLICATIONS

被引:7
作者
JEUSSET, J
STELLY, N
BRIANCON, C
HALPERN, S
ROSHANI, M
FRAGU, P
机构
[1] INST GUSTAVE ROUSSY,NUCL MED SERV,INSERM,EQUIPE MICROSCOPIE ION,F-94805 VILLEJUIF,FRANCE
[2] UNIV PARIS 11,BIOL CELLULAIRE LAB 4,CNRS,URA 1134,ORSAY,FRANCE
来源
JOURNAL OF MICROSCOPY-OXFORD | 1995年 / 179卷
关键词
SIMS MICROSCOPY; STANDARDIZATION; QUANTIFICATION; FLUORINE; CHLORINE; BROMINE; CALCIUM;
D O I
10.1111/j.1365-2818.1995.tb03647.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
The secondary ion mass spectrometry (SIMS) microscope is able to map chemical elements in tissue sections. Although absolute quantification of an element remains difficult, a relative quantitative approach is possible for soft tissue by using carbon (C-12) as an internal reference present at large homogeneous and constant concentration in specimen and embedding resin. In this study, this approach is used to standardize the signal of an SIMS microscope for the quantification of halogens (F-19(-), Cl-35(-) and Br-79(-)) and calcium (Ca-40(+)). Standard preparation was determined based on homogeneity and stability criteria by molecular incorporation (halogens) or mixing (calcium) in methacrylate resin. Standard measurements were performed by depth analysis on areas of 8 mu m (halogens) and 150 mu m (calcium) in diameter for 10-30 min, under Cs+ (halogens) or O-2(+) (calcium) bombardment. Results obtained from 100-120 measurements for each standard dilution show that the relationship between the signal intensity measured and the elemental concentration (mu g/mg of wet tissue or mM) is linear in the range of biological concentrations. This quantitative approach was applied firstly to bromine of the 5-bromo-2'-deoxyuridine (BrdU) used as nuclear marker of rat hepatocytes in proliferation. The second model concerns depletion of calcium concentration in cortical compartment in Paramecium tetraurelia during exocytosis. Then signal standardization in SIMS microscopy allows us to correlate quantitative results with those obtained from other methods.
引用
收藏
页码:314 / 320
页数:7
相关论文
共 34 条
[1]   QUANTITATIVE IMAGING OF BORON, CALCIUM, MAGNESIUM, POTASSIUM, AND SODIUM DISTRIBUTIONS IN CULTURED-CELLS WITH ION MICROSCOPY [J].
AUSSERER, WA ;
LING, YC ;
CHANDRA, S ;
MORRISON, GH .
ANALYTICAL CHEMISTRY, 1989, 61 (24) :2690-2695
[2]   IONIZATION PROBABILITY VARIATIONS DUE TO MATRIX IN ION MICROSCOPIC ANALYSIS OF PLASTIC-EMBEDDED AND ASHED BIOLOGICAL SPECIMENS [J].
BRENNA, JT ;
MORRISON, GH .
ANALYTICAL CHEMISTRY, 1986, 58 (08) :1675-1680
[3]   CHANGES IN I-127 MICE THYROID-FOLLICLE STUDIED BY ANALYTICAL ION MICROSCOPY - A KEY FOR THE COMPREHENSION OF AMIODARONE-INDUCED THYROID-DISEASES [J].
BRIANCON, C ;
HALPERN, S ;
TELENCZAK, P ;
FRAGU, P .
ENDOCRINOLOGY, 1990, 127 (03) :1502-1509
[4]   ACUTE EFFECTS OF VARIOUS DOSES OF IODIDE ON THYROID IODINE AUTOREGULATION - A STUDY WITH I-129 BY MEANS OF ANALYTICAL ION MICROSCOPY [J].
BRIANCON, C ;
HALPERN, S ;
JEUSSET, J ;
FRAGU, P .
BIOLOGICAL TRACE ELEMENT RESEARCH, 1992, 32 :267-273
[5]   QUANTITATIVE MICROLOCALIZATION OF DIFFUSIBLE IONS IN NORMAL AND GALACTOSE CATARACTOUS RAT LENS BY SECONDARY ION MASS-SPECTROMETRY [J].
BURNS, MS ;
FILE, DM .
JOURNAL OF MICROSCOPY-OXFORD, 1986, 144 :157-182
[6]   POLYATOMIC INTERFERENCES IN HIGH-RESOLUTION SECONDARY ION MASS-SPECTRA OF BIOLOGICAL TISSUES [J].
BURNS, MS .
ANALYTICAL CHEMISTRY, 1981, 53 (13) :2149-2152
[7]   DETECTION ON LIVER-TISSUE SECTIONS OF S-PHASE MARKERS IN SYNCHRONIZED CYCLING RAT HEPATOCYTES BY SIMS MICROSCOPY [J].
CASIRAGHI, O ;
LOMBARD, MN ;
HALPERN, S ;
FRAGU, P .
BIOLOGY OF THE CELL, 1993, 79 (03) :225-229
[8]  
Castaing R., 1962, J MICROSC-OXFORD, V1, P395
[9]  
CLERC J, 1993, J NUCL MED, V34, P1565
[10]  
CLERC J, 1995, J NUCL MED, V36, P859