RECEIVER OPERATING CHARACTERISTIC ANALYSIS OF CHEST IMAGE INTERPRETATION WITH CONVENTIONAL, LASER-PRINTED, AND HIGH-RESOLUTION WORKSTATION IMAGES

被引:112
作者
SLASKY, BS [1 ]
GUR, D [1 ]
GOOD, WF [1 ]
COSTAGRECO, MA [1 ]
HARRIS, KM [1 ]
COOPERSTEIN, LA [1 ]
ROCKETTE, HE [1 ]
机构
[1] UNIV PITTSBURGH,DEPT BIOSTAT,PITTSBURGH,PA 15261
关键词
Images; display; images; interpretation; storage and retrieval; lung; fibrosis; 60.91; nodule; 60.3221; radiography; 60.11; 60.1215; pneumothorax; 66.73; digital; receiver-operating characteristic curve (ROC);
D O I
10.1148/radiology.174.3.2305061
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The differences among radiologists in interpreting conventional and digitized images obtained with different radiologic procedures is an important research issue in these times of implementation and growth of the digital modalities. The authors performed a multiobserver study to determine the performance of radiologists reading posteroanterior conventional radiographs, digitized radiographs laser printed onto film, and images displayed on a high-resolution workstation (video monitor). A total of 300 images were evaluated by seven radiologists who recorded their ordinal confidence rating of the presence or absence of one or more of the following abnormalities: interstitial disease, nodule, and pneumothorax. Receiver operating characteristic analysis showed statistically significant differences for the detection of different abnormalities by individual readers. The group as a whole showed a significant reduction in observer performance for the detection of interstitial disease and pneumothorax when the laser-printed radiographs or the workstation was used rather than conventional radiographs.
引用
收藏
页码:775 / 780
页数:6
相关论文
共 22 条
[1]   A COMPARISON OF DUAL-ENERGY DIGITAL RADIOGRAPHY AND SCREEN-FILM IMAGING IN THE DETECTION OF SUBTLE INTERSTITIAL PULMONARY-DISEASE [J].
BARNES, GT ;
SABBAGH, EA ;
CHAKRABORTY, DP ;
NATH, PH ;
LUNA, RF ;
SANDERS, C ;
FRASER, RG .
INVESTIGATIVE RADIOLOGY, 1989, 24 (08) :585-591
[2]   DETECTION OF PNEUMOTHORAX - COMPARISON OF DIGITAL AND CONVENTIONAL CHEST IMAGING [J].
FAJARDO, LL ;
HILLMAN, BJ ;
POND, GD ;
CARMODY, RF ;
JOHNSON, JE ;
FERRELL, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) :475-480
[3]   THE EFFECT OF VARYING SPATIAL-RESOLUTION ON THE DETECTABILITY OF DIFFUSE PULMONARY NODULES - ASSESSMENT WITH DIGITIZED CONVENTIONAL RADIOGRAPHS [J].
FOLEY, WD ;
WILSON, CR ;
KEYES, GS ;
DIBIANCA, FA ;
SCANLON, GT ;
SCHLEUTER, D ;
LAWSON, TL .
RADIOLOGY, 1981, 141 (01) :25-31
[4]  
FRASER RG, 1983, RADIOLOGY, V148, P1
[5]   DIGITAL IMAGING OF THE CHEST [J].
FRASER, RG ;
SANDERS, C ;
BARNES, GT ;
MACMAHON, H ;
GIGER, ML ;
DOI, K ;
TEMPLETON, AW ;
COX, GG ;
DWYER, SJ ;
MERRITT, CRB ;
JONES, JP .
RADIOLOGY, 1989, 171 (02) :297-307
[6]   PNEUMOTHORAX AND OTHER LUNG-DISEASES - EFFECT OF ALTERED RESOLUTION AND EDGE ENHANCEMENT ON DIAGNOSIS WITH DIGITIZED RADIOGRAPHS [J].
GOODMAN, LR ;
FOLEY, WD ;
WILSON, CR ;
TIKOFSKY, RS ;
HOFFMANN, RG .
RADIOLOGY, 1988, 167 (01) :83-88
[7]   DIGITAL RADIOGRAPHY OF THE CHEST - PROMISES AND PROBLEMS [J].
GOODMAN, LR ;
WILSON, CR ;
FOLEY, WD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (06) :1241-1252
[8]   DIGITAL AND CONVENTIONAL CHEST IMAGES - OBSERVER PERFORMANCE WITH FILM DIGITAL RADIOGRAPHY SYSTEM [J].
GOODMAN, LR ;
FOLEY, WD ;
WILSON, CR ;
RIMM, AA ;
LAWSON, TL .
RADIOLOGY, 1986, 158 (01) :27-33
[9]   COMPARISON OF 2048-LINE DIGITAL-DISPLAY FORMATS AND CONVENTIONAL RADIOGRAPHS - AN ROC STUDY [J].
HAYRAPETIAN, A ;
ABERLE, DR ;
HUANG, HK ;
FISKE, R ;
MORIOKA, C ;
VALENTINO, D ;
BOECHAT, MI .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (05) :1113-1118
[10]   DIGITAL CHEST IMAGING - COMPARISON OF 2 FILM IMAGE DIGITIZERS WITH A CLASSIFICATION TASK [J].
KUNDEL, HL ;
MEZRICH, JL ;
BRICKMAN, I ;
SIEGEL, R ;
MILLER, WT ;
EPSTEIN, DM ;
GEFTER, WB ;
ARENSON, RL ;
SESHADRI, SB ;
KHALSA, S .
RADIOLOGY, 1987, 165 (03) :747-752