TRENDS IN DIAGNOSTIC ULTRASOUND EXPOSURE

被引:53
作者
DUCK, FA [1 ]
MARTIN, K [1 ]
机构
[1] NEWCASTLE GEN HOSP, DEPT MED PHYS, NEWCASTLE UPON TYNE NE4 6BE, TYNE & WEAR, ENGLAND
关键词
D O I
10.1088/0031-9155/36/11/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Trends in exposure for diagnostic ultrasonic equipment and a contemporary survey of exposure values are presented. It is demonstrated that both time-averaged intensities and peak pressures have increased steadily over the last two decades. Currently available diagnostic equipment generates pulses for which the average worst-case rarefaction pressure, p-, is about 2 MPa in water, irrespective of the mode of operation. Overall the highest values of p- are found in short-focus beams. Average spatial-peak time-averaged intensities, I(SPTA), are greatest for pulsed Doppler operation at a little over 1 W cm-2. M-mode and colour Doppler operation have average values of I(SPTA) of about 100 mW cm-2 and imaging operates at about an order of magnitude lower again. Vaginal transducers differ little in operational exposure from other transducers. Exposure measurement on colour Doppler systems demands a knowledge of the effect of scanner controls on the field, and some details are given.
引用
收藏
页码:1423 / 1432
页数:10
相关论文
共 30 条
[1]  
Allen K G, 1978, Physiotherapy, V64, P174
[2]  
Bly S. H. P., 1986, Canadian Acoustics, V14, P11
[3]  
CARSON P L, 1978, Ultrasound in Medicine and Biology, V3, P341, DOI 10.1016/0301-5629(78)90076-5
[4]   A SURVEY OF THE ACOUSTIC OUTPUT OF COMMERCIAL EXTRACORPOREAL SHOCK-WAVE LITHOTRIPTERS [J].
COLEMAN, AJ ;
SAUNDERS, JE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (03) :213-227
[5]   SURFACE HEATING OF DIAGNOSTIC ULTRASOUND TRANSDUCERS [J].
DUCK, FA ;
STARRITT, HC ;
TERHAAR, GR ;
LUNT, MJ .
BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (743) :1005-1013
[6]   OUTPUT DATA FROM EUROPEAN STUDIES [J].
DUCK, FA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 :61-64
[7]   A SURVEY OF THE ACOUSTIC OUTPUT OF ULTRASONIC DOPPLER EQUIPMENT [J].
DUCK, FA ;
STARRITT, HC ;
ANDERSON, SP .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1987, 8 (01) :39-49
[8]   AMPLITUDE-DEPENDENT LOSSES IN ULTRASOUND EXPOSURE MEASUREMENT [J].
DUCK, FA ;
PERKINS, MA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (02) :232-241
[9]   THE OUTPUT OF PULSE-ECHO ULTRASOUND EQUIPMENT - A SURVEY OF POWERS, PRESSURES AND INTENSITIES [J].
DUCK, FA ;
STARRITT, HC ;
AINDOW, JD ;
PERKINS, MA ;
HAWKINS, AJ .
BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (694) :989-1001
[10]  
DUCK FA, 1991, ULTRASONIC EXPOSIMET