OBSERVER EVALUATION OF SCATTER SUBTRACTION FOR DIGITAL PORTABLE CHEST RADIOGRAPHS

被引:3
作者
BAKER, JA
FLOYD, CE
LO, JY
RAVIN, CE
机构
[1] DUKE UNIV,MED CTR,DEPT RADIOL,DIV THORAC IMAGING RES,BOX 3949,DURHAM,NC 27710
[2] DUKE UNIV,DEPT BIOMED ENGN,DURHAM,NC 27706
关键词
RADIOGRAPHY; BEDSIDE; THORAX; COMPARATIVE STUDIES; TECHNOLOGY; MEDIASTINUM; CATHETERS AND CATHETERIZATION;
D O I
10.1097/00004424-199308000-00001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. The authors compared standard digital portable chest radiographs (DPCXR) to scatter-subtracted DPCXR. METHODS. Thirty DPCXR were obtained using a photostimulable phosphor digital imaging system and a posterior beam stop (PBS) technique that allowed measurement of the scatter component of the DPCXR. The scatter component was subtracted from the clinical image to form a scatter-subtracted image. Six observers recorded preference for the standard image or scatter-subtracted image for identifying five radiographic landmarks and for image quality. RESULTS. A statistically significant preference was demonstrated for the scatter-subtracted images and for viewing the tracheo-bronchial tree, right paratracheal stripe, vertebral column, and support apparatus position. For unprocessed images, there was a statistically significant preference for viewing the pulmonary vasculature. No statistically significant preference was demonstrated for overall image quality. CONCLUSIONS. These results suggest that PBS scatter subtraction holds promise for improving visualization of structures in high-scatter regions of chest radiographs.
引用
收藏
页码:667 / 670
页数:4
相关论文
共 22 条
[1]   SCATTER CORRECTION ALGORITHM FOR DIGITALLY ACQUIRED RADIOGRAPHS - THEORY AND RESULTS [J].
BOONE, JM .
MEDICAL PHYSICS, 1986, 13 (03) :319-328
[2]  
BUNGE RE, FDA808124 US DEP HLT, P172
[3]  
CURRY TS, 1984, CHRISTENSENS INTRO P, P88
[4]   QUANTITATIVE SCATTER MEASUREMENT IN DIGITAL RADIOGRAPHY USING A PHOTOSTIMULABLE PHOSPHOR IMAGING-SYSTEM [J].
FLOYD, CE ;
LO, JY ;
CHOTAS, HG ;
RAVIN, CE .
MEDICAL PHYSICS, 1991, 18 (03) :408-413
[5]   MEASUREMENT OF SCATTER FRACTIONS IN CLINICAL BEDSIDE RADIOGRAPHY [J].
FLOYD, CE ;
BAKER, JA ;
LO, JY ;
RAVIN, CE .
RADIOLOGY, 1992, 183 (03) :857-861
[6]   POSTERIOR BEAM-STOP METHOD FOR SCATTER FRACTION MEASUREMENT IN DIGITAL RADIOGRAPHY [J].
FLOYD, CE ;
BAKER, JA ;
LO, JY ;
RAVIN, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (02) :119-123
[7]   SCATTER COMPENSATION IN DIGITAL CHEST RADIOGRAPHY USING FOURIER DECONVOLUTION [J].
FLOYD, CE ;
BEATTY, PT ;
RAVIN, CE .
INVESTIGATIVE RADIOLOGY, 1989, 24 (01) :30-33
[8]  
GOODMAN LR, 1983, INTENSIVE CARE RADIO, P301
[9]  
HASSARD TH, 1991, UNDERSTANDING BIOSTA, P100
[10]  
JANOWER ML, 1984, AM J ROENTGENOL, V142, P265, DOI 10.2214/ajr.142.2.265