A FULLY AUTOMATED HPLC METHOD FOR THE DETERMINATION OF CATECHOLAMINES IN BIOLOGICAL SAMPLES UTILIZING ETHYLENEDIAMINE CONDENSATION AND PEROXYOXALATE CHEMILUMINESCENCE DETECTION

被引:45
作者
PRADOS, P [1 ]
HIGASHIDATE, S [1 ]
IMAI, K [1 ]
机构
[1] UNIV TOKYO,BRANCH HOSP PHARM,BUNKYO KU,TOKYO 112,JAPAN
关键词
D O I
10.1002/bmc.1130080102
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fully automated in-line extraction reversed-phase high-performance liquid chromatography (HPLC) method with chemiluminescence detection was developed for the analysis of human and Tat plasma catecholamines (CAs), norepinephrine (NE), epinephrine (E) and dopamine (DA). N-Methyldopamine (N-MeDA) was used as an internal standard. The method involves collection of plasma samples, which are first diluted with a sample dilution buffer containing N-MeDA, and in-line extraction of CAs using a carboxylic acid small resin precolumn (SERUMOUT-CEX). This pre-extraction process was coupled with an HPLC system including reversed-phase mode separation on an analytical column (TSK gel ODS-80Ts), fluorogenic derivatization with ethylenediamine (ED) and finally postcolumn peroxyoxalate chemiluminescence reaction detection using bis [4-nitro-2-(3,6,9-trioxadecyloxycarbonyl)phenyl]oxalate (TDPO) and hydrogen peroxide. The optimized mobile phase compositions, flow rates, operation timing for the adsorption and desorption of CAs in the precolumn, the separation in the analytical column and the optimum fluorogenic and chemiluminogenic reaction conditions were investigated. The detection limit for all the CAs was about 1 fmol (signal-to-noise ratio is 2). Excellent linearity of the calibration curves for CAs was observed in the range from 5 to 500 fmol for each CA using the internal standard. The relative standard deviations of the method for determining NE (183 fmol), E (23.6 fmol) and DA (6.1 fmol) in 50 muL of human plasma (n = 3) were 2.8, 2.7 and 3.1%, respectively, for the within-day assay and 5.0, 3.8 and 4.0%, respectively, for the between-day assay. The method was applicable to the determination of CAs in 25-50 muL of human or rat plasma.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 14 条
[1]   DETERMINATION OF CATECHOLAMINES IN URINE (AND PLASMA) BY LIQUID-CHROMATOGRAPHY AFTER ONLINE SAMPLE PRETREATMENT ON SMALL ALUMINA OR DIHYDROXYBORYLSILICA COLUMNS [J].
DEJONG, J ;
POINT, AJF ;
TJADEN, UR ;
BEEKSMA, S ;
KRAAK, JC .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 414 (02) :285-300
[2]   A SENSITIVE DOUBLE-ISOTOPE DERIVATIVE ASSAY FOR NOREPINEPHRINE AND EPINEPHRINE . NORMAL RESTING HUMAN PLASMA LEVELS [J].
ENGELMAN, K ;
PORTNOY, B .
CIRCULATION RESEARCH, 1970, 26 (01) :53-+
[3]  
GUPTA RN, 1988, J CHROMATOGR-BIOMED, V427, P359, DOI 10.1016/0378-4347(88)80142-7
[4]   DETERMINATION OF FEMTOMOLE CONCENTRATIONS OF CATECHOLAMINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMILUMINESCENCE DETECTION [J].
HIGASHIDATE, S ;
IMAI, K .
ANALYST, 1992, 117 (12) :1863-1868
[5]   THE ESTIMATION OF CATECHOLAMINES IN HUMAN-PLASMA [J].
HOLLY, JMP ;
MAKIN, HLJ .
ANALYTICAL BIOCHEMISTRY, 1983, 128 (02) :257-274
[6]  
KAMAHORI M, 1991, J CHROMATOGR, V567, P35
[7]  
Kitahashi T., 1991, RINSHO KAGAKU, V20, P24
[8]   DETERMINATION OF FLUORESCENT COMPOUNDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMI-LUMINESCENCE DETECTION [J].
KOBAYASHI, S ;
IMAI, K .
ANALYTICAL CHEMISTRY, 1980, 52 (03) :424-427
[9]  
MEFFORD JN, 1988, J CHROMATOGR, V427, P360
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PLASMA-CATECHOLAMINES USING 1,2-DIPHENYLETHYLENEDIAMINE AS PRECOLUMN FLUORESCENCE DERIVATIZATION REAGENT [J].
MITSUI, A ;
NOHTA, H ;
OHKURA, Y .
JOURNAL OF CHROMATOGRAPHY, 1985, 344 (NOV) :61-70