DEVELOPMENT OF POSTCOLUMN ENZYMATIC REACTORS WITH IMMOBILIZED ALCOHOL OXIDASE FOR USE IN THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF ALCOHOLS WITH ELECTROCHEMICAL DETECTION

被引:13
作者
TAGLIARO, F
SCHIAVON, G
DORIZZI, R
MARIGO, M
机构
[1] CNR,IPELP,I-35100 PADUA,ITALY
[2] HOSP LEGNAGO,CLIN CHEM LAB,VERONA,ITALY
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1991年 / 563卷 / 01期
关键词
D O I
10.1016/0378-4347(91)80273-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a very sensitive, direct injection high-performance liquid chromatographic method, using a post-column reactor with immobilized alcohol oxidase, was undertaken with the aim of determining methanol and ethanol levels in microlitre volumes of biological samples. After reversed-phase chromatography to separate methanol and ethanol, the analytes were enzymically converted into the respective aldehydes with formation of stoichiometric amounts of hydrogen peroxide, which could be measured via electrochemical oxidation at a platinum electrode. Some problems were encountered in the development of solid-phase enzymic reactors, using a delicate enzyme, that is prone to lose activity, such as alcohol oxidase. Owing to the slightly alkaline pH required for the optimum activity of alcohol oxidase, polymeric columns seemed to be preferable for the chromatography. HEMA copolymer was chosen as the stationary phase, but the methanol and ethanol peaks eluted close together and posed severe problems of limiting post-column band spreading. Reactors based on coarse supports for enzyme immobilization gave unacceptable band spreading, causing the methanol and ethanol peaks to overlap. On the other hand high-performance liquid chromatographic packings maintained the efficiency of the chromatographic separation, quite independently of the reactor volume. Polymeric supports proved superior to silicas in maintaining the enzyme activity. However, relevant changes in the enzyme substrate specificity were observed after immobilization.
引用
收藏
页码:11 / 21
页数:11
相关论文
共 18 条
[1]   ACETALDEHYDE, METHANOL, AND ETHANOL ANALYSIS BY HEADSPACE GAS-CHROMATOGRAPHY [J].
ANTHONY, RM ;
SUTHEIMER, CA ;
SUNSHINE, I .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1980, 4 (01) :43-45
[2]  
BASELT RC, 1982, DISPOSITION TOXIC DR, P299
[3]  
BELLJEANLEYMARI.M, 1989, ANN BIOL CLIN, V47, P144
[4]   APPLICATIONS OF IMMOBILIZED BIOCATALYSTS IN CHEMICAL-ANALYSIS [J].
BOWERS, LD .
ANALYTICAL CHEMISTRY, 1986, 58 (04) :A513-&
[6]   THE USE OF IMMOBILIZED ALCOHOL OXIDASE IN THE CONTINUOUS-FLOW DETERMINATION OF ETHANOL WITH AN OXYGEN-ELECTRODE [J].
GULBERG, EL ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1981, 123 (JAN) :125-133
[7]   INDIVIDUAL AND SIMULTANEOUS DETERMINATION OF ETHANOL AND ACETALDEHYDE IN WINES BY FLOW-INJECTION ANALYSIS AND IMMOBILIZED ENZYMES [J].
LAZARO, F ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1987, 59 (14) :1859-1863
[8]   SIMPLE APPROACH TO GAS-CHROMATOGRAPHIC MICROANALYSIS OF ALCOHOLS IN BLOOD AND URINE BY A DIRECT-INJECTION TECHNIQUE [J].
MANNO, BR ;
MANNO, JE .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1978, 2 (06) :257-261
[9]  
MARTIN E, 1986, Mitteilungen aus dem Gebiete der Lebensmitteluntersuchung und Hygiene, V77, P528
[10]  
PRENCIPE L, 1989, BIOCH CLIN, V13, P399