A simple and cheap assay suitable for screening for anti-HIV 1 and anti-HIV 2 and discriminating between them was evaluated. In it specimens are incubated in U-bottomed microplate wells coated with anti-human IgG for 30 min at room temperature. After washing, 100 mu l of a 1 in 50 dilution of HIV 1-coated gelatin particles (Serodia-HIV 1/2, Fujirebio) are added. Settling patterns are read on the second day: A positive reaction is indicated by adherence of the particles and a negative by a button. The HIV 1 particles a re then washed away a nd HIV 2 particles added. Anti-HIV 2 reaction patterns are read on the third day. To assess the performance of the modified ''GACPAT HIV 1+2'' assay a panel of 1,621 serum/plasma specimens was used. It comprised validated anti-HIV 1 positive (n = 220), anti-HIV 2 positive (n = 214), dual anti-HIV 1/antiHIV 2 positive (n = 11), and anti-HIV negative (n = 1,176) serum/plasma specimens. All 434 specimens that contained anti-HIV 1 or anti-HIV 2 reacted positively with the homologous particles. The 11 dually positive specimens reacted positively with both HIV 1 and HIV 2 particles. Five (2.3%) anti-HIV 1 and five (2.3%) anti-HIV 2 positive specimens gave positive reactions with both particle types, but none of the five cross-reactive anti-HIV 2 specimens were dually reactive when the order of particle addition was reversed. One repeat false positive reaction was recorded with the HIV 1 particles and none with the HIV 2 particles, giving specificities of 99.9% and 100%, respectively. Type specificity was 98.8% after the results of the reverse assay had been taken into account. The assay was sensitive for anti-HIV 1 in seroconversion series and for anti-HIV 2 in highly diluted specimens. GACPAT HIV 1 + 2 is an accurate anti-HIV assay applicable to serum/plasma. With few exceptions anti-HIV 1 positive specimens are reactive only on the second day and anti-HIV 2 positive specimens only on the third day. It thus discriminates anti-HIV 2 from anti-HIV 1, probably through depletion of cross-reacting antibodies by the reaction with the particles initially added. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:10 / 16
页数:7
相关论文
共 17 条
[1]   SENSITIVITY FOR ANTI-HIV-2 OF COMBINED HIV ANTIBODY KITS [J].
ABIOLA, PO ;
PARRY, JV ;
MORTIMER, PP .
LANCET, 1990, 336 (8727) :1386-1387
[2]   COMPETITIVE ENZYME-IMMUNOASSAYS USING NATIVE VIRAL-ANTIGENS TO DISCRIMINATE BETWEEN HIV-1 AND HIV-2 INFECTIONS [J].
BAILLOU, A ;
BARIN, F ;
LEONARD, G ;
DENIS, F ;
PETAT, E ;
FERREIRA, WFC ;
MBOUP, S ;
GOUDEAU, A .
JOURNAL OF VIROLOGICAL METHODS, 1990, 29 (01) :81-89
[3]   ACCURATE ASSAYS FOR ANTI-HIV IN URINE - PRELIMINARY-REPORT [J].
CONNELL, JA ;
PARRY, JV ;
MORTIMER, PP ;
DUNCAN, RJS ;
MCLEAN, KA ;
JOHNSON, AM ;
HAMBLING, MH ;
BARBARA, J ;
FARRINGTON, CP .
LANCET, 1990, 335 (8702) :1366-1369
[4]  
DADSWELL JV, 1992, PHLS COMMUN DIS REP, V2, pR126
[5]  
DENIS F, 1987, LANCET, V1, P324
[6]  
GNANN JW, 1987, SCIENCE, V237, P1436
[7]  
MCALPINE L, 1993, MDD9317 MED DEV DIR
[8]   DISCRIMINATION BETWEEN ANTIBODIES TO HIV AND TO RELATED RETROVIRUSES USING SITE-DIRECTED SEROLOGY [J].
NORRBY, E ;
BIBERFELD, G ;
CHIODI, F ;
VONGEGERFELDT, A ;
NAUCLER, A ;
PARKS, E ;
LERNER, R .
NATURE, 1987, 329 (6136) :248-250
[9]  
Parry J V, 1992, Commun Dis Rep CDR Rev, V2, pR128
[10]   SENSITIVITY OF 6 COMMERCIAL ENZYME-IMMUNOASSAY KITS THAT DETECT BOTH ANTI-HIV-1 AND ANTI-HIV-2 [J].
PARRY, JV ;
MCALPINE, L ;
AVILLEZ, MF .
AIDS, 1990, 4 (04) :355-360