REPRODUCIBILITY OF RETINAL NERVE-FIBER LAYER EVALUATION BY DYNAMIC SCANNING LASER OPHTHALMOSCOPY

被引:32
作者
MIGLIOR, S [1 ]
ROSSETTI, L [1 ]
BRIGATTI, L [1 ]
BUJTAR, E [1 ]
ORZALESI, N [1 ]
机构
[1] UNIV MILAN,S PAOLO HOSP,INST BIOMED SCI,DEPT OPHTHALMOL,MILAN,ITALY
关键词
D O I
10.1016/S0002-9394(14)72837-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Scanning laser ophthalmoscopy is a laser-based image acquisition technique, which greatly improves the quality of the examination of the fundus and the retinal nerve fil;er layer. To assess retinal nerve fiber layer imaging by scanning laser ophthalmoscopy and evaluate intra- and interobserver reproducibility in the classification of retinal nerve fiber layer defects, three independent observers evaluated on two separate occasions the videotaped images of 150 eyes of 80 consecutive patients with ocular hypertension or glaucoma. Ophthalmoscopy was performed using argon blue light (488 nm), confocal apertures of 3 to 1 mm, and 40-degree and 20-degree field angles. Of 150 eyes, 20 (13.3%) were excluded from the study because of the poor quality of the images (clinically significant cataract or myopic peripapillary atrophy). The retinal nerve fiber layer was evaluated qualitatively according to a standard classification: normal pattern, slit, wedge, and diffuse defects. Intraobserver reproducibility, evaluated by kappa statistic, was excellent (greater than or equal to 0.75): observer A = 0.78 (95% confidence limits, 0.67-0.88); observer B = 0.84 (95% confidence limits, 0.72-0.96); and observer C = 0.79 (95% confidence limits, 0.67-0.91). Interobserver reproducibility was also excellent in all cases: observers A-B = 0.84 (95% confidence limits, 0.71-0.98); observers A-C = 0.76 (95% confidence limits, 0.65-0.87); and observers B-C = 0.80 (95% confidence limits, 0.69-0.92). Kappa values ranged between 0.59 and 0.69 for intraobserver reproducibility and between 0.55 and 0.69 for interobserver reproducibility when using only those eyes in which abnormalities were noted by at least one observer. Retinal nerve fiber layer examination by means of argon blue scanning laser ophthalmoscopy proved to be clinically;suitable in a high proportion of patients and reliable in terms of the identification of defects.
引用
收藏
页码:16 / 23
页数:8
相关论文
共 29 条
[1]  
AIRAKSINEN PJ, 1985, ARCH OPHTHALMOL-CHIC, V103, P203
[2]  
AIRAKSINEN PJ, 1985, OPHTHALMOLOGY, V92, P877
[3]  
AIRAKSINEN PJ, 1984, AM J OPHTHALMOL, V98, P566, DOI 10.1016/0002-9394(84)90242-3
[4]  
AIRAKSINEN PJ, 1992, OPTIC NERVE GLAUCOMA, P277
[5]   SPECTRAL REFLECTANCE PHOTOGRAPHY OF RETINA [J].
BEHRENDT, T ;
WILSON, LA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1965, 59 (06) :1079-&
[6]  
BURK ROW, 1990, SCANNING LASER OPHTH, P161
[7]  
CAPRIOLI J, 1989, OPHTHALMOLOGY, V96, P633
[8]   MONOCHROMATIC OPHTHALMOSCOPY AND FUNDUS PHOTOGRAPHY - NORMAL FUNDUS [J].
DELORI, FC ;
GRAGOUDAS, ES ;
FRANCISCO, R ;
PRUETT, RC .
ARCHIVES OF OPHTHALMOLOGY, 1977, 95 (05) :861-868
[9]   REPRODUCIBILITY OF TOPOGRAPHIC MEASUREMENTS OF THE NORMAL AND GLAUCOMATOUS OPTIC-NERVE HEAD WITH THE LASER TOMOGRAPHIC SCANNER [J].
DREHER, AW ;
TSO, PC ;
WEINREB, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 111 (02) :221-229
[10]  
Fleiss JL, 2003, STAT METHODS RATES P, P598