HIGH-PRECISION GAMMA-RAY ENERGY MEASUREMENTS OF FISSION-PRODUCTS

被引:78
作者
BORNER, HG
DAVIDSON, WF
ALMEIDA, J
BLACHOT, J
PINSTON, JA
VANASSCHE, PHM
机构
[1] INST MAX VON LAUE PAUL LANGEVIN,F-38042 GRENOBLE,FRANCE
[2] CTR ETUDES NUCL,DEPT RECH FONDAMENTALE,F-38041 GRENOBLE,FRANCE
[3] CENS,F-91190 GIF SUR YVETTE,FRANCE
来源
NUCLEAR INSTRUMENTS & METHODS | 1979年 / 164卷 / 03期
关键词
D O I
10.1016/0029-554X(79)90097-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Curved crystal spectrometers have been used to obtain high-precision γ-ray energies below 1 MeV of fission product lines arising from neutron capture in 235U and 239Pu produced in in-pile targets of 234U and 238U, respectively. Assignments of these γ-transitions to fission isotopes have been made. © 1979.
引用
收藏
页码:579 / 586
页数:8
相关论文
共 11 条
[1]  
Blachot J., 1977, Atomic Data and Nuclear Data Tables, V20, P241, DOI 10.1016/0092-640X(77)90002-X
[2]   PRECISE ENERGIES OF K-RONTGEN-LINES OF TM, TH, U AND PU [J].
BORCHERT, GL .
ZEITSCHRIFT FUR NATURFORSCHUNG SECTION A-A JOURNAL OF PHYSICAL SCIENCES, 1976, 31 (01) :102-104
[3]  
BORNER H, 1974, 2ND P INT S NEUTR CA, P691
[4]  
BORNER HG, 1976, THESIS TU MUNCHEN
[5]   REDETERMINATION OF AU-198 AND IR-192 GAMMA-RAY STANDARDS BETWEEN 0.1 AND 1.0 MEV [J].
KESSLER, EG ;
DESLATTES, RD ;
HENINS, A ;
SAUDER, WC .
PHYSICAL REVIEW LETTERS, 1978, 40 (03) :171-174
[6]   JULICH ONLINE SEPARATOR FOR FISSION-PRODUCTS JOSEF [J].
LAWIN, H ;
EIDENS, J ;
BORGS, JW ;
FABBRI, R ;
GRUTER, JW ;
JOSWIG, G ;
KHAN, TA ;
LAUPPE, WD ;
SADLER, G ;
SELIC, HA ;
SHAANAN, M ;
SISTEMICH, K ;
ARMBRUSTER, P .
NUCLEAR INSTRUMENTS & METHODS, 1976, 137 (01) :103-117
[7]   BESTIMMUNG DES (631)K=1/2,I=1/2-ZUSTANDES IM U239 [J].
MAIER, BPK .
ZEITSCHRIFT FUR PHYSIK, 1965, 184 (02) :143-&
[8]   3-PARTICLE ONE-HOLE CONFIGURATIONS IN ODD-ODD I-134 AND DECAY OF TE-134 [J].
MEYER, RA ;
LANDRUM, JH ;
JACKSON, SV ;
ZOLLER, WH ;
WALTERS, WB .
PHYSICAL REVIEW C, 1976, 13 (04) :1617-1623
[9]   ANALYSIS OF U-236-FISSION PRODUCTS BY RECOIL SEPARATOR LOHENGRIN [J].
MOLL, E ;
SCHRADER, H ;
SIEGERT, G ;
ASGHAR, M ;
BOCQUET, JP ;
BAILLEUL, G ;
GAUTHERON, JP ;
GREIF, J ;
CRAWFORD, GI ;
CHAUVIN, C ;
EWALD, H ;
WOLLNIK, H ;
ARMBRUSTER, P ;
FIEBIG, G ;
LAWIN, H ;
SISTEMICH, K .
NUCLEAR INSTRUMENTS & METHODS, 1975, 123 (03) :615-617
[10]   ONLINE MASS-SEPARATOR FOR THERMICALLY IONIZABLE FISSION-PRODUCTS - OSTIS [J].
WUNSCH, KD .
NUCLEAR INSTRUMENTS & METHODS, 1978, 155 (03) :347-351