FPD - BURNER CONFIGURATIONS AND THE RESPONSE TO HETERO-ORGANICS

被引:11
作者
KAPILA, S
VOGT, CR
机构
[1] Environmental Trace Substances Research Center, University of Missouri, Columbia, MO
基金
美国国家科学基金会;
关键词
D O I
10.1093/chromsci/17.6.327
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Dependence of flame photometric detector response on burner design and other parameters, such as flow rates of H2, O2, air, and mode of mixing was investigated. These parameters affected the response of sulfur, phosphorus, and arsenic test compounds to a varying degree. Addition of helium to the flame caused an enhancement in sulfur and phosphorus response, and a 3-fold increase in S/N ratio was obtained. With optimized conditions, a minimum detectable limit of about 3 pg methyl parathion was obtained. Under suitable conditions good sensitivity and selectivity (over carbon) were observed for triphenyl arsine. © 1979, Oxford University Press. All rights reserved.
引用
收藏
页码:327 / 332
页数:6
相关论文
共 40 条
[1]   RESPONSE OF A FILTER-LESS FLAME PHOTOMETRIC DETECTOR TO HETERO-ORGANICS [J].
AUE, WA ;
HASTINGS, CR .
JOURNAL OF CHROMATOGRAPHY, 1973, 87 (01) :232-235
[2]   PHOTOMETRIC TIN DETECTOR FOR GAS-CHROMATOGRAPHY [J].
AUE, WA ;
FLINN, CG .
JOURNAL OF CHROMATOGRAPHY, 1977, 142 (NOV) :145-154
[3]  
AUE WA, 1978, J CHROMATOGR, V158, P153
[4]   MOLECULAR-EMISSION CAVITY ANALYSIS .10. SEPARATION AND SIMULTANEOUS DETERMINATION OF ARSENIC AND ANTIMONY BY HYDRIDE GENERATION [J].
BELCHER, R ;
BOGDANSKI, SL ;
HENDEN, E ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1977, 92 (01) :33-41
[5]   MOLECULAR EMISSION CAVITY ANALYSIS (MECA) - NEW FLAME ANALYTICAL TECHNIQUE .4. DETERMINATION OF ARSENIC AND ANTIMONY [J].
BELCHER, R ;
BOGDANSK.SL ;
GHONAIM, SA ;
TOWNSHEN.A .
ANALYTICA CHIMICA ACTA, 1974, 72 (01) :183-187
[7]   SOLID ADSORBENT PRECONCENTRATION AND GAS-CHROMATOGRAPHIC ANALYSIS OF SULFUR GASES [J].
BLACK, MS ;
HERBST, RP ;
HITCHCOCK, DR .
ANALYTICAL CHEMISTRY, 1978, 50 (07) :848-851
[8]   ARSENIC IN DRINKING-WATER OF CITY OF ANTOFAGASTA - EPIDEMIOLOGICAL AND CLINICAL-STUDY BEFORE AND AFTER INSTALLATION OF A TREATMENT-PLANT [J].
BORGONO, JM ;
VICENT, P ;
VENTURINO, H ;
INFANTE, A .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1977, 19 (AUG) :103-105
[9]   GAS CHROMATOGRAPHIC DETECTOR FOR SIMULTANEOUS SENSING OF PHOSPHORUS- AND SULFUR- CONTAINING COMPOUNDS BY FLAME PHOTOMETRY [J].
BOWMAN, MC ;
BEROZA, M .
ANALYTICAL CHEMISTRY, 1968, 40 (10) :1448-&
[10]   DIRECT VOLATILIZATION SPECTRAL EMISSION TYPE DETECTION SYSTEM FOR NANOGRAM AMOUNTS OF ARSENIC AND ANTIMONY [J].
BRAMAN, RS ;
FOREBACK, CC ;
JUSTEN, LL .
ANALYTICAL CHEMISTRY, 1972, 44 (13) :2195-&