EVALUATION OF THE AUTOMATED BACT-ALERT SYSTEM FOR PEDIATRIC BLOOD CULTURING

被引:10
作者
PICKETT, DA
WELCH, DF
机构
[1] UNIV OKLAHOMA,HLTH SCI CTR,CLIN MICROBIOL LABS,OKLAHOMA CITY,OK
[2] UNIV OKLAHOMA,HLTH SCI CTR,DEPT PEDIAT,OKLAHOMA CITY,OK 73190
关键词
BACTEREMIA; BLOOD CULTURE; PEDIATRICS; SEPTICEMIA; DIAGNOSIS; BACT/ALERT; ISOLATOR;
D O I
10.1093/ajcp/103.3.320
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
The Organon Teknika BacT/Alert (Organon Teknika, Durham, NC), using the Pedi-BacT 20 mt aerobic bottle (BPBCS) was compared to the Wampole Isolator (WI) 1.5 Microbial tube (Wampole Laboratories, Cranbury, NJ), for detection and recovery of pediatric pathogens. The BPBCS continuously monitors culture bottles for changes in CO2 concentrations, while WI cultures are examined twice daily for appearance of colonial growth on agar media. Of 5,175 paired blood cultures, 383 pathogens were recovered from 606 positive cultures. There were 272 pathogens recovered by both systems, 64 from BPBCS only, and 47 from WI only. Overall recovery rates were 88% for BPBCS and 83% for WI. There was no significant difference between the two systems in detection or times to positivity of staphylococci, Enterobacteriaceae, or pseudomonads. Trends toward better recovery of streptococci (20 vs. 10) and fastidious microaerophiles (3 vs. 0) were found with BPBCS, whereas more slow ly growing pathogens (Rochalimaea henselae [1], Mycobacterium avium-intracellulare [1]) were recovered by WI only, but because of their lower frequency did not achieve statistical significance. Detection of Haemophilus influenzae (14.9 hours in WI vs. 45.4 hours in BPBCS) was faster with WI. False positive plus contaminant cultures were detected in 5.9% BPBCS versus 1.5% WI. BPBCS offers detection of bacteremia at a rate comparable to WI with advantages of automation.
引用
收藏
页码:320 / 323
页数:4
相关论文
共 15 条
[1]   EVALUATION OF A LYSIS-CENTRIFUGATION SYSTEM FOR RECOVERY OF YEASTS AND FILAMENTOUS FUNGI FROM BLOOD [J].
BILLE, J ;
STOCKMAN, L ;
ROBERTS, GD ;
HORSTMEIER, CD ;
ILSTRUP, DM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 18 (03) :469-471
[2]   TIME TO DETECTION OF POSITIVE BACT ALERT BLOOD CULTURES AND LACK OF NEED FOR ROUTINE SUBCULTURE OF 5-DAY TO 7-DAY NEGATIVE CULTURES [J].
HARDY, DJ ;
HULBERT, BB ;
MIGNEAULT, PC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (10) :2743-2745
[3]   ROUTINE AEROBIC TERMINAL SUBCULTURING OF BLOOD CULTURES IN A CANCER HOSPITAL [J].
KIEHN, TE ;
WONG, B ;
EDWARDS, FF ;
ARMSTRONG, D .
JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 18 (04) :885-889
[4]   COMPARATIVE RECOVERY OF BACTERIA AND YEASTS FROM LYSIS-CENTRIFUGATION AND A CONVENTIONAL BLOOD CULTURE SYSTEM [J].
KIEHN, TE ;
WONG, B ;
EDWARDS, FF ;
ARMSTRONG, D .
JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 18 (02) :300-304
[5]   MYCOBACTERIUM-TUBERCULOSIS BACTEREMIA DETECTED BY THE ISOLATOR LYSIS-CENTRIFUGATION BLOOD CULTURE SYSTEM [J].
KIEHN, TE ;
GOLD, JWM ;
BRANNON, P ;
TIMBERGER, RJ ;
ARMSTRONG, D .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 21 (04) :647-648
[6]   COMPARISON OF THE BACT ALERT PEDIATRIC BLOOD CULTURE SYSTEM, PEDI-BACT, WITH CONVENTIONAL CULTURE USING THE 20-MILLILITER BECTON-DICKINSON SUPPLEMENTED PEPTONE BROTH TUBE [J].
KRISHER, KK ;
WHYBURN, DR ;
KOEPNICK, FE .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (04) :793-797
[7]   CLINICAL ANATOMY - A NEW CHALLENGE [J].
MARTINEZALMAGRO, A .
SURGICAL AND RADIOLOGIC ANATOMY, 1993, 15 (01) :1-3
[8]  
RELLER LB, 1982, BLOOD CULTURES, V2
[9]   FAILURE OF THE BACTEC 460 RADIOMETER TO DETECT CRYPTOCOCCUS NEOFORMANS FUNGEMIA IN AN AIDS PATIENT [J].
ROBINSON, PG ;
SULITA, MJ ;
MATTHEWS, EK ;
WARREN, JR .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1987, 87 (06) :783-786
[10]   A NEWLY RECOGNIZED FASTIDIOUS GRAM-NEGATIVE PATHOGEN AS A CAUSE OF FEVER AND BACTEREMIA [J].
SLATER, LN ;
WELCH, DF ;
HENSEL, D ;
COODY, DW .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (23) :1587-1593