MEASUREMENT OF MINUTE VENTILATION IN VENTILATOR-DEPENDENT PATIENTS - NEED FOR STANDARDIZATION

被引:14
作者
YANG, KL
TOBIN, MJ
机构
[1] Division of Pulmonary Medicine, University of Texas, Hlth. Science Cntr. at Houston, Houston, TX 77030
关键词
MECHANICAL VENTILATION; RESPIRATORS; RESPIRATORY WEANING; WEANING PARAMETERS; PULMONARY MECHANICS; PULMONARY FUNCTION TESTS; RESPIRATORY MONITORING; SURVEY METHODS; SPIROMETRY; TIDAL VOLUME; LUNG VOLUME MEASUREMENTS; INTENSIVE CARE UNITS;
D O I
10.1097/00003246-199101000-00014
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: a) To determine the variation in methods used to measure minute ventilation (VE) in patients who receive mechanical ventilation; b) to determine the effect of supplemental oxygen on VE, respiratory rate (RR), and tidal volume (VT) measurements. Design: Telephone survey of hospitals, and a randomized control trial. Setting: Medical and surgical ICUs in a university hospital. Patients: Thirty-three patients who had required mechanical ventilation because of the inability to sustain adequate spontaneous ventilation. All patients were considered ready to undergo a weaning trial by their physicians. Interventions: Spontaneous VE, RR, VT, and SaO2 were measured both in the presence and absence of supplemental oxygen; measurements were obtained in a randomized manner. Measurements and Main Results: a) In a telephone survey of hospitals throughout the country, we found that the measurement of VE is variably obtained during room air breathing or in the presence of supplemental oxygen. b) Measurements of VE increased from 11.0 +/- 0.8 L/min while patients received supplemental oxygen to 13.5 +/- 1.1 L/min while patients breathed room air (p < .001). Of 15 patients who had a VE < 10 L/min while receiving supplemental oxygen, seven developed a value > 10 L/min while breathing room air; thus, a weaning trial might have been inappropriately deferred in these patients. c) Mean SaO2 decreased from 95.0 +/- 0.6% while breathing supplemental oxygen to 90.2 +/- 1.1% while breathing room air (p < .001). Conclusions: Measurements of VE in patients being considered for a weaning trial can result in significant oxygen desaturation if obtained during room air breathing, and the values obtained can significantly overestimate the patient's true ventilatory requirements, since most patients receive supplemental oxygen during a weaning trial. Standardized methods of measuring VE in critically ill patients need to be developed.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 12 条
  • [1] [Anonymous], 1987, Am Rev Respir Dis, V136, P1285
  • [2] EVALUATION OF 2 DIFFERENT EXTUBATION CRITERIA - ATTRIBUTES CONTRIBUTING TO SUCCESS
    DEHAVEN, CB
    HURST, JM
    BRANSON, RD
    [J]. CRITICAL CARE MEDICINE, 1986, 14 (02) : 92 - 94
  • [3] COMPARISON OF STANDARD WEANING PARAMETERS AND THE MECHANICAL WORK OF BREATHING IN MECHANICALLY VENTILATED PATIENTS
    FIASTRO, JF
    HABIB, MP
    SHON, BY
    CAMPBELL, SC
    [J]. CHEST, 1988, 94 (02) : 232 - 238
  • [4] PREDICTION OF SUCCESSFUL VENTILATOR WEANING USING AIRWAY OCCLUSION PRESSURE AND HYPERCAPNIC CHALLENGE
    MONTGOMERY, AB
    HOLLE, RHO
    NEAGLEY, SR
    PIERSON, DJ
    SCHOENE, RB
    [J]. CHEST, 1987, 91 (04) : 496 - 499
  • [5] NETT LM, 1984, CRITICAL CARE COMPRE, P171
  • [6] PARDEE NE, 1985, CHEST, V85, P203
  • [7] DIAPHRAGMATIC FATIGUE AND BREATHING PATTERN DURING WEANING FROM MECHANICAL VENTILATION IN COPD PATIENTS
    POURRIAT, JL
    LAMBERTO, C
    HOANG, PH
    FOURNIER, JL
    VASSEUR, B
    [J]. CHEST, 1986, 90 (05) : 703 - 707
  • [8] BEDSIDE CRITERIA FOR DISCONTINUATION OF MECHANICAL VENTILATION
    SAHN, SA
    LAKSHMIN.S
    [J]. CHEST, 1973, 63 (06) : 1002 - 1005
  • [9] Stetson JB, 1970, INT ANAESTHESIOL CLI, V8, P774
  • [10] EXTUBATION CRITERIA AFTER WEANING FROM INTERMITTENT MANDATORY VENTILATION AND CONTINUOUS POSITIVE AIRWAY PRESSURE
    TAHVANAINEN, J
    SALMENPERA, M
    NIKKI, P
    [J]. CRITICAL CARE MEDICINE, 1983, 11 (09) : 702 - 707