PERCUTANEOUS RENAL BIOPSY WITH THE USE OF REAL-TIME ULTRASOUND

被引:51
作者
BURSTEIN, DM
SCHWARTZ, MM
KORBET, SM
机构
[1] RUSH MED COLL,DEPT MED,CHICAGO,IL 60612
[2] RUSH MED COLL,DEPT PATHOL,CHICAGO,IL 60612
关键词
PERCUTANEOUS RENAL BIOPSY; REAL-TIME ULTRASOUND;
D O I
10.1159/000168303
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
We describe our experience with real-time ultrasound as a localization and guidance tool for percutaneous renal biopsy. Two hundred biopsies performed between June 1983 and January 1990 were reviewed retrospectively. Nephrology fellows performed 83.5% of the biopsies. The average age of the patients was 43 +/- 17 years (range 6-80) and renal insufficiency (serum creatinine greater-than-or-equal-to 1.3 mg, %) was present in approximately 60% of patients biopsied. Primary indications for biopsy were to evaluate proteinuria (46.5%) and renal manifestation of systemic lupus erythematosus (24%). Material for light microscopy, immunofluorescence, and electron microscopy was obtained in 99.5, 95.0 and 98.0% of cases, respectively. Adequate tissue for histologic diagnosis was obtained in 97.5% of patients. Primary diagnosis was glomerulonephritis in 77.9% of cases. Complications were assessed and separated by severity. Total complications were observed in 13.7% of patients with 8.1% of these being minor complications (not requiring blood transfusion) and 5.6% being major complications which required blood transfusions. Bleeding complications requiring massive blood transfusion and/or therapeutic radiologic intervention were seen in 1.5% of patients. We could find no significant difference with respect to age, serum creatinine, or coagulation parameters between patients with or without complications due to percutaneous renal biopsy. We conclude that real-time ultrasound is a safe, accurate method in localizing the kidney for percutaneous renal blopsy. However, patients must still be observed carefully post biopsy for potential complications.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 22 条
[1]   PERCUTANEOUS KIDNEY BIOPSIES - COMPLICATIONS AND THEIR MANAGEMENT [J].
ALTEBARMAKIAN, VK ;
GUTHINGER, WP ;
YAKUB, YN ;
GUTIERREZ, OH ;
LINKE, CA .
UROLOGY, 1981, 18 (02) :118-122
[2]   AN IMPROVED TECHNIQUE FOR ULTRASOUND GUIDED PERCUTANEOUS RENAL BIOPSY [J].
BIRNHOLZ, JC ;
KASINATH, BS ;
CORWIN, HL .
KIDNEY INTERNATIONAL, 1985, 27 (01) :80-82
[3]   LOCALIZATION OF KIDNEY FOR PERCUTANEOUS BIOPSY - COMPARATIVE STUDY OF METHODS [J].
BOLTON, WK ;
TULLY, RJ ;
LEWIS, EJ ;
RANNIGER, K .
ANNALS OF INTERNAL MEDICINE, 1974, 81 (02) :159-164
[4]  
Diaz-Buxo J A, 1975, Clin Nephrol, V4, P223
[5]   ULTRASONIC LOCALIZATION FOR RENAL BIOPSY [J].
GOLDBERG, BB ;
POLLACK, HM ;
KELLERMAN, E .
RADIOLOGY, 1975, 115 (01) :167-170
[6]  
Goldman M L, 1975, Urology, V6, P386, DOI 10.1016/0090-4295(75)90778-5
[7]   PERCUTANEOUS RENAL BIOPSY - AN IMPROVED METHOD USING TELEVISION MONITORING AND HIGH-DOSE INFUSION PYELOGRAPHY [J].
HADDAD, JK ;
MANI, RL .
ARCHIVES OF INTERNAL MEDICINE, 1967, 119 (02) :157-&
[8]   ASPIRATION BIOPSY OF THE KIDNEY [J].
IVERSEN, P ;
BRUN, C .
AMERICAN JOURNAL OF MEDICINE, 1951, 11 (03) :324-330
[9]   RENAL BIOPSY [J].
KARK, RM .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 205 (04) :220-&
[10]  
KARK RM, 1966, LANCET, V1, P904