CONTINUOUS CARDIAC-OUTPUT MONITORING BY THE FICK METHOD

被引:4
作者
BAXLEY, WA [1 ]
CAVENDER, JB [1 ]
KNOBLOCK, J [1 ]
机构
[1] UNIV ALABAMA, MED CTR, BIRMINGHAM, AL 35294 USA
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1993年 / 28卷 / 01期
关键词
FIBEROPTIC CATHETERS; METABOLIC ANALYSIS; OXYGEN CONSUMPTION;
D O I
10.1002/ccd.1810280118
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Current methods for longitudinal assessment of cardiac output in severely ill patients are intermittent only and in many respects appear unsatisfactory. We have developed a computerized on-line system for continuous Fick cardiac output monitoring, utilizing fiberoptic arterial and pulmonary arterial probes with a metabolic analyzer for VO2. In 15 patients, cardiac output ranged 1.9-6.8 L/min and 12 were within 5% of thermodilution values. Continuous output monitoring during interventions in two patients (saline infusion and coronary angioplasty) illustrate the utility of the technique. Two additional patients had unsatisfactory VO2 data due to low airflow velocity. The results of this pilot study suggest that cardiac output monitoring by the Fick method may have clinical and investigational uses in intensive care units and during cardiac catheterization or surgical procedures.
引用
收藏
页码:89 / 92
页数:4
相关论文
共 11 条
[1]  
ANSTADT M P, 1992, Journal of the American College of Cardiology, V19, p135A
[2]   ON-LINE COMPUTER ANALYSIS AND BREATH-BY-BREATH GRAPHICAL DISPLAY OF EXERCISE FUNCTION TESTS [J].
BEAVER, WL ;
WASSERMAN, K ;
WHIPP, BJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1973, 34 (01) :128-132
[3]   CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN HEMODYNAMICALLY UNSTABLE PATIENTS [J].
BIRMAN, H ;
HAQ, A ;
HEW, E ;
ABERMAN, A .
CHEST, 1984, 86 (05) :753-756
[4]   CONTINUOUS FICK CARDIAC-OUTPUT COMPARED TO THERMODILUTION CARDIAC-OUTPUT [J].
DAVIES, GG ;
JEBSON, PJR ;
GLASGOW, BM ;
HESS, DR .
CRITICAL CARE MEDICINE, 1986, 14 (10) :881-885
[5]   USE OF CONTINUOUS MONITORING OF MIXED VENOUS SATURATION IN THE CORONARY-CARE UNIT [J].
GORE, JM ;
SLOAN, K .
CHEST, 1984, 86 (05) :757-761
[6]  
JAMIESON WRE, 1982, CAN J SURG, V25, P538
[7]   THERMODILUTION CARDIAC-OUTPUT - CRITICAL ANALYSIS AND REVIEW OF THE LITERATURE [J].
LEVETT, JM ;
REPLOGLE, RL .
JOURNAL OF SURGICAL RESEARCH, 1979, 27 (06) :392-404
[8]   GUIDE WIRE-SHEATH TECHNIQUE FOR PULMONARY-ARTERY CATHETERIZATION AND CENTRAL VEIN CANNULATION [J].
MCMICHAN, JC ;
MICHEL, L .
INTENSIVE CARE MEDICINE, 1979, 5 (01) :37-39
[9]   RELIABILITY OF THE DETERMINATION OF CARDIAC OUTPUT IN MAN BY MEANS OF THE FICK PRINCIPLE [J].
SELZER, A ;
SUDRANN, RB .
CIRCULATION RESEARCH, 1958, 6 (04) :485-490
[10]  
SHAPIRO B A, 1992, Respiratory Care, V37, P165