A METHOD FOR A FULLY-AUTOMATIC DEFINITION OF CORONARY ARTERIAL EDGES FROM CINEANGIOGRAMS

被引:66
作者
EICHEL, PH
DELP, EJ
KORAL, K
BUDA, AJ
机构
[1] PURDUE UNIV,SCH ELECT ENGN,COMP VIS & IMAGE PROC LAB,W LAFAYETTE,IN 47907
[2] UNIV MICHIGAN,DEPT INTERNAL MED,DIV CARDIOL,ANN ARBOR,MI 48109
关键词
Biological Materials--Blood Vessels - Image Processing--Image Analysis - Mathematical Techniques--Algorithms;
D O I
10.1109/42.14514
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The authors describe a novel algorithm, known as sequential edge linking (SEL), for the automatic definition of coronary arterial edges in cineangiograms. This algorithm is based on sequential tree searching of possible coronary artery boundary locations. Using a coronary artery phantom, the authors compared the results obtained using SEL with hand-traced boundaries. Using a magnification of 2×, the results are generally good, with the average error being 1.7% of the diameter. Actual coronary artery images were also processed and a similar comparison indicated that total areas were comparable but the hand-drawn stenoses were, on average, 7% greater than the unobstructed diameter. Based on these data it is concluded that the SEL algorithm is an accurate method for fully automatic definition of coronary artery dimensions.