STUDY OF POLYORGANOSILOXANES (NATIVE AND SOLVENT SWOLLEN) FOR THE PREPARATION OF NARROW (5-15 MU-M ID) AND LONG (1-6 M) OPEN-TUBULAR COLUMNS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY

被引:16
作者
GOHLIN, K
LARSSON, M
机构
[1] GOTHENBURG UNIV,S-41296 GOTHENBURG,SWEDEN
[2] ASTRA HASSLE AB,S-43183 MOLNDAL,SWEDEN
来源
JOURNAL OF CHROMATOGRAPHY | 1993年 / 645卷 / 01期
关键词
D O I
10.1016/0021-9673(93)80616-G
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Narrow-bore, (5-15 mum), long (up to 6 m), efficient and stable open tubular columns with four different polyorganosiloxane coatings, were prepared by the static coating and the precipitation coating methods. The polysiloxanes were substituted with phenyl- (OV-17-vi and PS-264), methyl- (PS-255), and octadecyl- (PMSC18) groups. They were studied in their regular cross-linked state as well as after swelling with n-heptane. Anthracene derivatives were used as model compounds. Column properties such as retention, selectivity and efficiency were investigated in reversed-phase liquid chromatography. GC was used for complementary studies of 50 mum I.D. columns. The highest retention was obtained on the columns coated with OV-17-vi and on the swelled stationary phases. A considerable resolution improvement was obtained in the columns, after swelling with n-heptane owing to the increase in retention. More than 10(6) theoretical plates were achieved in 70 min at a k' of 0.46 in a 6 m x 6 mum I.D. column.
引用
收藏
页码:41 / 56
页数:16
相关论文
共 55 条
[1]   RAYLEIGH INSTABILITY OF STATIONARY PHASE FILMS IN CAPILLARY COLUMN CHROMATOGRAPHY [J].
BARTLE, KD ;
WOOLLEY, CL ;
MARKIDES, KE ;
LEE, ML ;
HANSEN, RS .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (03) :128-136
[2]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[3]  
Dandeneau R.D., 1979, J HIGH RESOLUT CHROM, V2, P351, DOI [10.1002/jhrc.1240020617, DOI 10.1002/JHRC.1240020617]
[4]   NEW METHOD FOR THE PREPARATION OF SMALL DIAMETER COLUMNS WITH POLYMERIC STATIONARY PHASES FOR OPEN TUBULAR LIQUID-CHROMATOGRAPHY [J].
DLUZNESKI, PR ;
JORGENSON, JW .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (04) :332-336
[5]  
DLUZNESKI PR, 1987, THESIS U N CARLOINA
[6]   EFFICIENCY, RESOLUTION AND SPEED OF OPEN TUBULAR COLUMNS AS COMPARED TO PACKED-COLUMNS [J].
ETTRE, LS ;
MARCH, EW .
JOURNAL OF CHROMATOGRAPHY, 1974, 91 (APR24) :5-24
[7]  
EUGUCHI S, 1990, J CHROMATOGR, V516, P301
[8]   POLYMERIZED STATIONARY PHASES IN 12 TO 50-MU-M OPEN TUBULAR FUSED-SILICA COLUMNS FOR LC AND GC [J].
FARBROT, A ;
FOLESTAD, S ;
LARSSON, M .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (02) :117-119
[9]   SWOLLEN POLYSILOXANES AS STATIONARY PHASES IN REVERSED-PHASE OPEN-TUBULAR COLUMN LIQUID-CHROMATOGRAPHY [J].
FOLESTAD, S ;
LARSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1987, 394 (03) :455-464
[10]   SMALL-BORE LC LASER FLUORESCENCE [J].
FOLESTAD, S ;
GALLE, B ;
JOSEFSSON, B .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1985, 23 (06) :273-278