摘要
An in vitro study was done using a fluid filtration device to compare microleakage of Temporary Endodontic Restorative Material (TERM) at various thicknesses. Forty-four extracted mandibular molars had their roots removed at the cementoenamel junction, occlusal table flattened, and a standardized endodontic access made in the crown. The teeth were restored with TERM in thicknesses of 1, 2, 3, and 4 mm, and quantitatively measured for leakage (microliters/min) at intervals of 1 and 24 h and 1, 3, and 5 wk. Thermocycling was accomplished at the 5-wk interval. Positive controls received 4-mm-thick IRM or gutta-percha restorations and were measured at 24 h only. Repeated measures of analysis of variance found no significant difference (p < 0.05) in leakage values in any group over time or between any of the different thicknesses. Positive controls showed significantly more leakage than all other groups. TERM maintained as tight a seal at 1-, 2-, and 3-mm thicknesses as it did at 4 mm and may be suited for clinical situations where less than 4 mm of restorative space exists.
引用
收藏
页码:448 / 452
页数:5
相关论文
共 20 条
[1]   MICROLEAKAGE OF 3 TEMPORARY ENDODONTIC RESTORATIONS [J].
ANDERSON, RW ;
POWELL, BJ ;
PASHLEY, DH .
JOURNAL OF ENDODONTICS, 1988, 14 (10) :497-501
[2]  
BARKHORDAR RA, 1990, ORAL SURG, V569, P99
[3]   MARGINAL SEALING QUALITY OF IRM AND CAVIT AS ASSESSED BY MICROBIAL PENETRATION [J].
BLANEY, TD ;
PETERS, DD ;
SETTERSTROM, J ;
BERNIER, WE .
JOURNAL OF ENDODONTICS, 1981, 7 (10) :453-457
[4]   A MICROLEAKAGE STUDY OF TEMPORARY RESTORATIVE MATERIALS USED IN ENDODONTICS [J].
BOBOTIS, HG ;
ANDERSON, RW ;
PASHLEY, DH ;
PANTERA, EA .
JOURNAL OF ENDODONTICS, 1989, 15 (12) :569-572
[5]  
Cvek M, 1978, J Endod, V4, P232, DOI 10.1016/S0099-2399(78)80153-8
[6]   MICROLEAKAGE MEASUREMENT OF SELECTED RESTORATIVE MATERIALS - A NEW INVITRO METHOD [J].
DERKSON, GD ;
PASHLEY, DH ;
DERKSON, ME .
JOURNAL OF PROSTHETIC DENTISTRY, 1986, 56 (04) :435-440
[7]  
GROSSMAN LI, 1939, JD RES, V18, P67
[8]   EFFECTS OF SURGICAL EXPOSURES OF DENTAL PULPS IN GERM-FREE AND CONVENTIONAL LABORATORY RATS [J].
KAKEHASHI, S ;
STANLEY, HR ;
FITZGERALD, RJ .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1965, 20 (03) :340-+
[9]  
MAROSKY J E, 1977, Journal of Endodontics, V3, P110, DOI 10.1016/S0099-2399(77)80205-7
[10]   A COMPARISON OF 2 TEMPORARY RESTORATIONS - LIGHT-CURED RESIN VERSUS A SELF-POLYMERIZING TEMPORARY RESTORATION [J].
MELTON, D ;
COBB, S ;
KRELL, KV .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1990, 70 (02) :221-225