REPEAT DILATION OF INTRAVASCULAR STENTS IN CONGENITAL HEART-DEFECTS

被引:104
作者
ING, FF
GRIFKA, RG
NIHILL, MR
MULLINS, CE
机构
[1] TEXAS CHILDRENS HOSP, DEPT PEDIAT CARDIOL, HOUSTON, TX 77030 USA
[2] SCHNEIDER CHILDRENS HOSP, DEPT PEDIAT CARDIOL, NEW HYDE PK, NY USA
关键词
STENTS; RESTENOSIS; HEART DEFECTS; CONGENITAL;
D O I
10.1161/01.CIR.92.4.893
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Intravascular (Palmaz) stents have been successfully implanted in patients with congenital and acquired branch pulmonary stenosis. Early results are excellent; however, there is no information on restenosis and repeat dilation in patients with congenital heart disease. The purpose of this study is to review the incidence of restenosis and demonstrate the safety and efficacy of repeat dilation of stents in this group of patients. Methods and Results Of 94 patients with 163 implanted stents in this single-center study, 43 patients with 73 implanted stents underwent recatheterization. Only 2 of 73 restudied stents (3%) developed significant restenosis. In 20 patients, 30 stents were redilated. At stent implantation, the mean age of this subgroup was 14.2 years, the mean intraluminal diameter increased from 4.9 to 10.7 mm (P=.0001), and the systolic gradient (mean) across the stent decreased from 52 to 11 mm Hg (P=.0001). At recatheterization (mean, 13 months), all stents were patent. The mean diameter decreased by 1.2 mm (P=.0001), but the increase in the gradient (mean, 3 mm Hg) was not significant (P=.11). After repeat dilation, the diameter increased from 9.5 to 12.2 mm (P=.0001), and the gradient decreased from 14 to 8 mm Hg (P=.0003). The 2 stents with restenosis were redilated successfully. Two patients underwent a successful second redilation of 3 stents at 18 and 26 months. There were no complications. Conclusions All stents remained patent. The occurrence of significant restenosis is low (3%), and these restenoses can be redilated and/or restented. Repeat dilation of the Palmaz stent implanted in branch pulmonary artery stenosis can be per formed with safety and efficacy (94% success rate) up to 3 years after stent implantation.
引用
收藏
页码:893 / 897
页数:5
相关论文
共 37 条
  • [1] ALFIERI O, 1978, J THORAC CARDIOV SUR, V76, P321
  • [2] MANAGEMENT OF RESTENOSIS WITHIN THE PALMAZ-SCHATZ CORONARY STENT (THE UNITED-STATES MULTICENTER EXPERIENCE)
    BAIM, DS
    LEVINE, MJ
    LEON, MB
    LEVINE, S
    ELLIS, SG
    SCHATZ, RA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (04) : 364 - 366
  • [3] CONGENITAL STENOSIS OF PULMONARY ARTERY BRANCHES
    BAUM, D
    ONGLEY, PA
    KINCAID, OW
    KHOURY, GH
    SWAN, HJC
    [J]. CIRCULATION, 1964, 29 (05) : 680 - &
  • [4] BLACKSTONE EH, 1979, J THORAC CARDIOV SUR, V78, P542
  • [5] ANGIOGRAPHIC AND CLINICAL OUTCOME OF INTRACORONARY STENTING - IMMEDIATE AND LONG-TERM RESULTS FROM A LARGE SINGLE-CENTER EXPERIENCE
    CARROZZA, JP
    KUNTZ, RE
    LEVINE, MJ
    POMERANTZ, RM
    FISHMAN, RF
    MANSOUR, M
    GIBSON, CM
    SENERCHIA, CC
    DIVER, DJ
    SAFIAN, RD
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) : 328 - 337
  • [6] A NOVEL METHOD TO MAINTAIN DUCTUS-ARTERIOSUS PATENCY
    COE, JY
    OLLEY, PM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (03) : 837 - 841
  • [7] PRELIMINARY-OBSERVATIONS ON THE USE OF THE PALMAZ STENT IN THE DISTAL PORTION OF THE ABDOMINAL-AORTA
    DIETHRICH, EB
    SANTIAGO, O
    GUSTAFSON, G
    HEUSER, RR
    [J]. AMERICAN HEART JOURNAL, 1993, 125 (02) : 490 - 501
  • [8] TRANSLUMINALLY-PLACED COILSPRING ENDARTERIAL TUBE GRAFTS - LONG-TERM PATENCY IN CANINE POPLITEAL ARTERY
    DOTTER, CT
    [J]. INVESTIGATIVE RADIOLOGY, 1969, 4 (05) : 329 - +
  • [9] SAFETY, SUCCESS, AND RESTENOSIS AFTER ELECTIVE CORONARY IMPLANTATION OF THE PALMAZ-SCHATZ STENT IN 100 PATIENTS AT A SINGLE CENTER
    FOLEY, JB
    PENN, IM
    BROWN, RIG
    MURRAYPARSONS, N
    WHITE, J
    GALLIGAN, L
    MACDONALD, C
    [J]. AMERICAN HEART JOURNAL, 1993, 125 (03) : 686 - 694
  • [10] GIBBS JL, 1992, BRIT HEART J, V67, P240