PLASMA LIPID ANALYSIS BY THIN-LAYER CHROMATOGRAPHY WITH FLAME IONIZATION DETECTION AND QUANTITATION

被引:35
作者
BRADLEY, DM
RICKARDS, CR
THOMAS, NST
机构
[1] Department of Medicine, Welsh National School of Medicine, Cardiff, CF4 4XN, Heath Park
关键词
D O I
10.1016/0009-8981(79)90126-8
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A method is presented whereby cholesterol, cholesterol ester, triacylglycerol, non-esterified fatty acid and polar lipid in plasma may be simultaneously quantitated. Following the addition of umbelliferyl palmitate as internal standard, plasma (0.1 ml) is extracted with chloroform/methanol (2:1, v/v). A portion of the extract is chromatographed on silica gel fused to a narrow cylindrical quartz rod. After chromatography the rod is traversed through a flame ionisation detector and the responses recorded and integrated. The procedure is shown to be sensitive, linear, reproducible and to compare well with conventional methods for the determination of plasma lipid classes. © 1979.
引用
收藏
页码:293 / 302