ALIGNMENT TECHNIQUES FOR CALIBRATION AND INSTALLATION OF A 6-M TOROIDAL GRATING MONOCHROMATOR

被引:10
作者
WALLACE, DJ
HANSEN, RWC
PERKINS, FK
PRUETT, CH
WELNAK, J
机构
[1] University of Wisconsin-Madison, Synchrotron Radiation Center, Stoughton, WI 53589
基金
美国国家科学基金会;
关键词
D O I
10.1016/0168-9002(90)90067-G
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The University of Wisconsin Synchrotron Radiation Center Optics Group has recently completed the installation of three 6-m Toroidal Grating Monochromator (TGM) beamlines on the Aladdin ring. Two of these beamlines image bending-magnet radiation and the third images radiation from the 30-period undulator on loan to the Synchrotron Radiation Center from the Stanford Synchrotron Radiation Laboratory and Lawrence Berkeley Laboratory. Each beamline required an accurate alignment strategy. This is due to the long source-to-final-image distance and the five independent critical elements: entrance mirror, entrance slit, grating chamber, exit slit, and exit mirror. The TGM grating chamber houses up to six gratings on a revolving carousel which is scanned with a sine-drive. We will describe grating stability checks and adjustments to linearize the grating scan calibration. We will also outline the basic alignment procedures from the source point, through the grating chamber, to the final focus. The procedure we have used provided sufficiently accurate alignment to realize the high throughput and resolution capabilities of the 6-m TGMs. The methods also allow later checks on critical degrees of freedom of the optical components. © 1990.
引用
收藏
页码:231 / 236
页数:6
相关论文
共 10 条
[1]   6-M TGM IMPLEMENTATION AT THE WISCONSIN-SYNCHROTRON-RADIATION-CENTER (SRC) [J].
COLE, RK ;
PERKINS, FK ;
BRODSKY, EL ;
FILIPPONI, A ;
KORPELLA, E ;
MANCINI, DC ;
PRUETT, CH ;
WALLACE, DJ ;
WELNAK, JT ;
ZANINI, F .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :2093-2096
[2]   IMPLEMENTATION OF AN UNDULATOR BEAMLINE ON ALADDIN [J].
HANSEN, RWC ;
BRODSKY, EL ;
PRUETT, CH ;
WALLACE, DJ ;
KORPELA, E ;
FILIPPONI, A ;
BISSEN, M ;
WELNAK, JT ;
GREEN, MA ;
TRZECIAK, WS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2) :162-167
[3]   AN ULTRAHIGH-VACUUM MULTIPLE GRATING CHAMBER AND SCAN DRIVE WITH IMPROVED GRATING CHANGE [J].
HULBERT, SL ;
HOLLY, DJ ;
MIDDLETON, FH ;
WALLACE, DJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2) :343-347
[4]  
KISSAM P, 1962, OPTICAL TOOLING
[5]  
MCGRAE JD, 1964, OPTICAL TOOLING IND
[6]   NEW SYNCHROTRON RADIATION CENTER BEAMLINES AT ALADDIN [J].
PRUETT, CH ;
BRODSKY, EL ;
COLE, RK ;
CROSSLEY, SL ;
CROSSLEY, DB ;
HANSEN, RWC ;
NELSON, T ;
PERKINS, FK ;
ROGERS, GC ;
ROSENBERG, RA ;
WALLACE, DJ ;
WINTER, WR ;
MIDDLETON, FH ;
FILIPPONI, A ;
ZANINI, F .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1913-1916
[7]   EXPERIMENTALLY DETERMINED RESOLUTION OF A 6 METER TOROIDAL GRATING MONOCHROMATOR [J].
ROSE, JL ;
MANCINI, DC ;
WELNAK, JT ;
COLE, RK .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2) :192-201
[8]  
SAWYER RA, 1963, EXPT SPECTROSCOPY, P165
[9]   A 6 M TOROIDAL-GRATING-MONOCHROMATOR BEAM LINE FOR HIGH MOMENTUM RESOLUTION PHOTOELECTRON-SPECTROSCOPY [J].
THIRY, P ;
BENNETT, PA ;
KEVAN, SD ;
ROYER, WA ;
CHABAN, EE ;
ROWE, JE ;
SMITH, NV .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 222 (1-2) :85-90
[10]  
WAGNER MK, UNPUB COMMUNICATION