A COMBINED CELLOBIOSE OXIDASE GLUCOSE-OXIDASE BIOSENSOR FOR HPLC DETERMINATION ONLINE OF GLUCOSE AND SOLUBLE CELLODEXTRINES

被引:40
作者
NORDLING, M [1 ]
ELMGREN, M [1 ]
STAHLBERG, J [1 ]
PETTERSSON, G [1 ]
LINDQUIST, SE [1 ]
机构
[1] UNIV UPPSALA,BMC,DEPT BIOCHEM,S-75105 UPPSALA,SWEDEN
关键词
D O I
10.1006/abio.1993.1513
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Highly specific biosensors can be prepared by immobilizing flavin-containing oxidases in a redox polymer on an electrode surface. By combining one glucose oxidase and one cellobiose oxidase electrode in a flow cell we have made a sensor for flow-injection analysis, or postcolumn quantification, of glucose, cellobiose, and higher cellodextrines in an HPLC system. Samples of different concentrations of glucose and cellobiose, separately or mixed, were injected into the mobile phase and the current response was recorded simultaneously from both electrodes. The recorded response peak heights could be used for calibration curves. The usable measuring ranges were roughly 50 μM-50 mM for glucose and 5 μM-80 mM for cellobiose. Soluble cellodextrines, Glc(1-6), could be separated on a C18 column by isocratic elution and detected by the sensor. © 1993 Academic Press, Inc.
引用
收藏
页码:389 / 396
页数:8
相关论文
共 23 条
[1]   CELLOBIOSE OXIDASE, PURIFICATION AND PARTIAL CHARACTERIZATION OF A HEMOPROTEIN FROM SPOROTRICHUM-PULVERULENTUM [J].
AYERS, AR ;
AYERS, SB ;
ERIKSSON, KE .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1978, 90 (01) :171-181
[2]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[3]   CELLOBIOSE OXIDASE CROSS-LINKED IN A REDOX POLYMER MATRIX AT AN ELECTRODE SURFACE - A NEW BIOSENSOR [J].
ELMGREN, M ;
LINDQUIST, SE ;
HENRIKSSON, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 341 (1-2) :257-273
[4]  
GIBSON QH, 1964, J BIOL CHEM, V239, P3927
[5]   A GLUCOSE ELECTRODE BASED ON CARBON PASTE CHEMICALLY MODIFIED WITH A FERROCENE-CONTAINING SILOXANE POLYMER AND GLUCOSE-OXIDASE, COATED WITH A POLY(ESTER-SULFONIC ACID) CATION-EXCHANGER [J].
GORTON, L ;
KARAN, HI ;
HALE, PD ;
INAGAKI, T ;
OKAMOTO, Y ;
SKOTHEIM, TA .
ANALYTICA CHIMICA ACTA, 1990, 228 (01) :23-30
[6]   REDOX POLYMER-FILMS CONTAINING ENZYMES .1. A REDOX-CONDUCTING EPOXY CEMENT - SYNTHESIS, CHARACTERIZATION, AND ELECTROCATALYTIC OXIDATION OF HYDROQUINONE [J].
GREGG, BA ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1991, 95 (15) :5970-5975
[7]   CROSS-LINKED REDOX GELS CONTAINING GLUCOSE-OXIDASE FOR AMPEROMETRIC BIOSENSOR APPLICATIONS [J].
GREGG, BA ;
HELLER, A .
ANALYTICAL CHEMISTRY, 1990, 62 (03) :258-263
[8]   REDOX POLYMER-FILMS CONTAINING ENZYMES .2. GLUCOSE-OXIDASE CONTAINING ENZYME ELECTRODES [J].
GREGG, BA ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1991, 95 (15) :5976-5980
[9]   ELECTRICAL WIRING OF REDOX ENZYMES [J].
HELLER, A .
ACCOUNTS OF CHEMICAL RESEARCH, 1990, 23 (05) :128-134
[10]   ELECTRICAL CONNECTION OF ENZYME REDOX CENTERS TO ELECTRODES [J].
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (09) :3579-3587