DOPPLER FLOW VELOCITY-MEASUREMENTS DURING CORONARY ANGIOPLASTY

被引:3
作者
DILL, H [1 ]
ALTSTIDL, R [1 ]
REGENFUS, M [1 ]
LEHMKUHL, H [1 ]
BACHMANN, K [1 ]
机构
[1] UNIV ERLANGEN NUREMBERG,MED KLIN 2,DEPT CARDIOL,OESTLICHE STADTMAUERSTR 29,D-91054 ERLANGEN,GERMANY
关键词
D O I
10.1177/000331979404501007
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
In addition to further studies using Doppler catheters to assess blood flow velocity during coronary angioplasty this study intends to evaluate the functional significance of coronary stenoses and to estimate their hemodynamic relevance prior to and after percutaneous transluminal coronary angioplasty (PTCA). Diameters of coronary artery stenoses were quantified by means of the cardiovascular angiographic analysis system (CAAS) both prior to and following successful PTCA in 37 patients. During coronary artery angioplasty a 12 M:Hz 0.018-in. Doppler-tipped guidewire was used to measure prestenotic and post-stenotic parameters of coronary artery flow velocity both prior to and following PTCA. The minimal stenosis diameter was raised from 1.01 +/-0.58 to 1.76 +/-0.73 mm (P < 0.0001), the percent diameter stenosis decreased from 63 +/-11 to 35 +/-6% (P < 0.0001). Prestenotic average (APV) and maximum peak velocity (MPV), peak velocity integral (PVI), average systolic (ASPV) and diastolic (ADPV) peak velocity, systolic (SPVI) and diastolic (DPVI) peak velocity integral, and diastolic/systolic velocity ratio showed - in contrast to further studies - a considerably significant difference (P < 0.05), whereas poststenotic Doppler data (APV, MPV, PVI, ASPV, DSPV, SPVI, DPVI, DSVR) differed highly significantly (P < 0.0001) prior to and following PTCA. Prestenotic and poststenotic measurements of coronary artery flow velocity differed significantly before and after PTCA and offer the potential for estimating both the hemodynamic relevance of coronary artery stenoses and success of PTCA.
引用
收藏
页码:877 / 882
页数:6
相关论文
共 30 条
[1]   NEW METHOD TO MEASURE PHASIC CORONARY BLOOD VELOCITY IN MAN [J].
BENCHIMOL, A ;
STEGALL, HF ;
GARTLAN, JL .
AMERICAN HEART JOURNAL, 1971, 81 (01) :93-+
[2]   PULSED DOPPLER CORONARY-ARTERY CATHETER - PRELIMINARY-REPORT OF A NEW TECHNIQUE FOR MEASURING RAPID CHANGES IN CORONARY-ARTERY FLOW VELOCITY IN MAN [J].
COLE, JS ;
HARTLEY, CJ .
CIRCULATION, 1977, 56 (01) :18-25
[3]   CALIBRATION USING ANGIOGRAPHIC CATHETERS AS SCALING DEVICES - IMPORTANCE OF FILMING THE CATHETERS NOT FILLED WITH CONTRAST-MEDIUM [J].
DIMARIO, C ;
HERMANS, WRM ;
RENSING, BJ ;
SERRUYS, PW .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (16) :1377-1378
[4]  
DORIOT PA, 1992, NEW DEV QUANTITATIVE, P115
[5]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[6]   HEMODYNAMIC DETERMINATIONS IN ASSESSMENT OF DISTAL CORONARY-ARTERY DISEASE [J].
FURUSE, A ;
KLOPP, EH ;
BRAWLEY, RK ;
GOTT, VL .
JOURNAL OF SURGICAL RESEARCH, 1975, 19 (01) :25-33
[7]   PHYSIOLOGIC BASIS FOR ASSESSING CRITICAL CORONARY STENOSIS - INSTANTANEOUS FLOW RESPONSE AND REGIONAL DISTRIBUTION DURING CORONARY HYPEREMIA AS MEASURES OF CORONARY FLOW RESERVE [J].
GOULD, KL ;
LIPSCOMB, K ;
HAMILTON, GW .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01) :87-94
[8]   THE VALUE OF LESION CROSS-SECTIONAL AREA DETERMINED BY QUANTITATIVE CORONARY ANGIOGRAPHY IN ASSESSING THE PHYSIOLOGIC SIGNIFICANCE OF PROXIMAL LEFT ANTERIOR DESCENDING CORONARY ARTERIAL STENOSES [J].
HARRISON, DG ;
WHITE, CW ;
HIRATZKA, LF ;
DOTY, DB ;
BARNES, DH ;
EASTHAM, CL ;
MARCUS, ML .
CIRCULATION, 1984, 69 (06) :1111-1119
[9]   ULTRASONIC PULSED DOPPLER SYSTEM FOR MEASURING BLOOD-FLOW IN SMALL VESSELS [J].
HARTLEY, CJ ;
COLE, JS .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 37 (04) :626-629
[10]   ASSESSMENT OF SEVERITY OF CORONARY STENOSES USING A DOPPLER CATHETER - VALIDATION OF A METHOD BASED ON THE CONTINUITY EQUATION [J].
JOHNSON, EL ;
YOCK, PG ;
HARGRAVE, VK ;
SREBRO, JP ;
MANUBENS, SM ;
SEITZ, W ;
PORTS, TA .
CIRCULATION, 1989, 80 (03) :625-635