HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF THE NOVEL ANTITUMOR DRUG TOPOTECAN AND TOPOTECAN AS THE TOTAL OF THE LACTONE PLUS CARBOXYLATE FORMS, IN HUMAN PLASMA

被引:92
作者
ROSING, H
DOYLE, E
DAVIES, BE
BEIJNEN, JH
机构
[1] SMITHKLINE BEECHAM PHARMACEUT,DEPT DRUG METAB & PHARMACOKINET,WELWYN GARDEN CIT AL6 9AR,HERTS,ENGLAND
[2] SMITHKLINE BEECHAM PHARMACEUT,DEPT DRUG METAB & PHARMACOKINET,KING OF PRUSSIA,PA 19406
[3] UNIV UTRECHT,FAC PHARM,DEPT PHARMACEUT ANAL & TOXICOL,3511 GH UTRECHT,NETHERLANDS
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1995年 / 668卷 / 01期
关键词
D O I
10.1016/0378-4347(95)00054-M
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive high-performance liquid chromatographic (HPLC) assay has been developed and validated for the quantitation of the novel anticancer agent topotecan and topotecan as the total of its lactone and carboxylate forms in human plasma. Linear response in analyte standard peak area were observed over the concentration range 0.05-10 ng/ml using 100-mu l plasma samples. The instability of the drug in the biological matrix necessitated that the plasma fraction was obtained within 5 min after blood sampling by centrifugation, immediately followed by protein precipitation with cold methanol (-30 degrees C). Stability studies have indicated that topotecan is stable in these methanolic extracts for at least 4.5 months at -30 degrees C and 2 months at -70 degrees C. For the total determination of the lactone plus lactone ring-opened forms of the drug as topotecan, plasma samples were deproteinated with methanol and, subsequently, acidified with 7% (v/v) perchloric acid. Plasma samples for the measurement of total levels of the lactone and the ring-opened forms of topotecan were stable for at least 4.5 months when stored at -30 degrees C. After centrifugation, the supernatants were analysed by HPLC using a Zorbax SB-C-18 Stable Bond column and methanol-0.1 M hexane-1-sulfonic acid in methanol-0.01 M N,N,N',N'-tetramethylethylenediamine (TEMED) in distilled water pH 6.0 (25:10:65, v/v) as the mobile phase. Detection was performed fluorimetrically. Within-run and between-run precision was always less than 12.1% in the concentration range of interest (0.05-10.0 ng/ml). The limit of quantitation is 0.05 ng/ml. Accuracy measurements ranged between 87.6 and 113.5%.
引用
收藏
页码:107 / 115
页数:9
相关论文
共 22 条
[1]  
Kingsbury, Boehm, Jakas, Holde, Hecht, Gallagher, Caranfa, McCabe, Faucette, Johnson, Synthesis of water-soluble (aminoalkyl)camptothecin analogs: inhibition of topoisomerase I and antitumor activity, Journal of Medicinal Chemistry, 34, (1989)
[2]  
Cummings, Smyth, Ann. Oncol., 4, (1993)
[3]  
Slichenmeyer, Rowinsky, Donehower, Kaufmann, The Current Status of Camptothecin Analogues as Antitumor Agents, JNCI Journal of the National Cancer Institute, 85, (1993)
[4]  
Burris, Hanauske, Johnson, Marshall, Kuhn, Hilsenbeck, Von Hoff, J. Natl. Canc. Inst., 84, (1992)
[5]  
Rowinsky, Grochow, Hendricks, Ettinger, Forastiere, Hurowitz, McGuire, Sartorius, Lubejko, Kaufmann, Donehower, J. Clin. Oncol., 10, (1992)
[6]  
Verweij, Lund, Beijnen, Planting, de Boer-Dennert, Koier, Rosing, Hansen, Ann. Oncol., 4, (1993)
[7]  
Hochster, Liebes, Speyer, Sorich, Taubes, Oratz, Wernz, Chachoua, Raphael, Vinci, Blum, J. Clin. Oncol., 12, (1994)
[8]  
Pratt, Stewart, Santana, Bowman, Furman, Ochs, Marina, Kuttesch, Heideman, Sandlund, Avery, Meyer, J. Clin. Oncol., 12, (1994)
[9]  
Blaney, Balis, Cole, Craig, Reid, Ames, Krailo, Reaman, Hammond, Poplack, Cancer Res., 53, (1993)
[10]  
Wall, Burris, Von Hoff, Rodriguez, Kneuper-Hall, Shaffer, O'Rourke, Brown, Weiss, Clark, McVea, Brown, Johnson, Friedman, Smith, Mann, Kuhn, Anti-Cancer Drugs, 3, (1992)