AGREEMENT BETWEEN CLINICIAN AND A CONFOCAL SCANNING LASER OPHTHALMOSCOPE IN ESTIMATING CUP/DISK RATIOS

被引:92
作者
ZANGWILL, L
SHAKIBA, S
CAPRIOLI, J
WEINREB, RN
机构
[1] UNIV CALIF SAN DIEGO, DEPT OPHTHALMOL, GLAUCOMA CTR & RES LABS 0964, LA JOLLA, CA 92093 USA
[2] YALE UNIV, DEPT OPHTHALMOL & VISUAL SCI, NEW HAVEN, CT 06510 USA
关键词
D O I
10.1016/S0002-9394(14)71226-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: We assessed agreement between cup/disk ratio measurements obtained by glaucoma expert evaluation of stereoscopic photographs of the optic disk and those obtained with a confocal scanning laser ophthalmoscope. METHODS: Three glaucoma experts estimated vertical and horizontal cup/disk ratios from stereoscopic photographs of 15 normal subjects and 15 patients with glaucoma. These estimates were compared to vertical, horizontal, and area cup/disk ratios measured witch a confocal scanning laser ophthalmoscope. Intraobserver and interobserver agreements were also estimated. RESULTS: Agreement between clinicians and the confocal scanning laser ophthalmoscope varied by clinician. Agreement was moderate to substantial for vertical cup/disk ratio and fair to moderate for horizontal cup/disk ratio; kappas ranged from 0.57 to 0.72 and from 0.21 to 0.55, respectively. The mean confocal scanning laser ophthalmoscope area cup/disk ratio measurements were smaller than each clinician's mean vertical and horizontal cup/disk ratio estimates; differences ranged from 0.10 to 0.24 and from 0.06 to 0.16, respectively. Differences were smaller between clinician estimates and instrument measurements of horizontal and vertical cup/disk ratios of patients with glaucoma than normal subjects. CONCLUSIONS: These results demonstrate good agreement between confocal scanning laser ophthalmoscope measurements and clinician estimates of the vertical cup/disk ratios from stereoscopic photographs, particularly of patients with glaucoma. However, as differences between clinician and instrument estimates of cup/disk ratios were found, new quantitative criteria must be established for characterizing a disk as glaucomatous using confocal scanning laser ophthalmoscopy.
引用
收藏
页码:415 / 421
页数:7
相关论文
共 11 条
  • [1] Kahn HA, Leibowitz H, Ganley JP, Kini M, Colton T, Nickerson R, Et al., Randomized controlled clinical trial: National Eye Institute workshop for ophthalmologists: standardizing diagnostic procedures, Am J Ophthalmol, 79, pp. 768-775, (1975)
  • [2] Lichter PR, Variability of expert observers in evaluating the optic disc, Trans Am Ophthalmol Soc, 74, pp. 532-572, (1976)
  • [3] Klein BEK, Magli YL, Richie KA, Moss SE, Meuer SM, Klein R, Quantitation of optic disc cupping, Ophthalmology, 92, pp. 1654-1656, (1985)
  • [4] Tielsch JM, Katz J, Quigley HA, Miller NR, Sommer A, Intraobserver and interobserver agreement in measurement of optic disc characteristics, Ophthalmology, 95, pp. 350-356, (1988)
  • [5] Varma R, Spaeth GL, Steinmann WC, Katz LJ, Agreement between clinicians and an image analyzer in estimating cup-to-disc ratios, Arch Ophthalmol, 107, pp. 526-529, (1989)
  • [6] Weinreb RN, Lusky M, Bartsch DU, Morsman D, Effect of repetitive imaging on topographic measurements of the optic nerve head, Arch Ophthalmol, 111, pp. 636-638, (1993)
  • [7] Mikelberg FS, Wijsman K, Schulzer M, Reproducibility of topographic parameters obtained with the Heidelberg Retina Tomograph, J Glaucoma, 2, pp. 101-103, (1993)
  • [8] Zeyen TG, Caprioli J, Progression of disc and field damage in early glaucoma, Arch Ophthalmol, 111, pp. 62-65, (1993)
  • [9] Fleiss JL, pp. 212-236, (1981)
  • [10] Landis JR, Koch GG, The measurement of observer agreement for categorical data, Biometrics, 33, pp. 159-174, (1977)