COMPARISON OF COMPUTED DENSITY AND MACROSCOPIC MORPHOMETRY IN PULMONARY-EMPHYSEMA

被引:492
作者
GEVENOIS, PA
DEMAERTELAER, V
DEVUYST, P
ZANEN, J
YERNAULT, JC
机构
[1] HOP ERASME, DEPT CHEST MED, B-1070 BRUSSELS, BELGIUM
[2] FREE UNIV BRUSSELS, IRIBHN, STAT UNIT, BRUSSELS, BELGIUM
[3] UNIV MONS, SERV HISTOL, B-7000 MONS, BELGIUM
关键词
D O I
10.1164/ajrccm.152.2.7633722
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
High-resolution computed tomography (HRCT) scans were obtained at 1 cm intervals in 63 subjects referred for surgical resection of a cancer or for transplantation to find out whether the relative area of lung occupied by attenuation values lower than a threshold would be a measurement of macroscopic emphysema. Using a semiautomatic procedure, the relative areas occupied by attenuation values lower than eight thresholds ranging from -900 to -970 HU were calculated on the set of scans obtained through the lobe or the lung to be resected. The extent of emphysema was quantified by a computer-assisted method on horizontal paper-mounted lung sections obtained every 1 to 2 cm. The only level for which no statistically significant difference was found between the HRCT and the morphometric data was -950 HU. To determine the number of scans sufficient for an accurate quantification, we recalculated the relative area occupied by attenuation values lower than -950 HU on progressively fewer numbers of scans and investigated the departure from the results obtained with 1 cm intervals. Because of wide variations in this departure from patient to patient, a standard cannot be recommended as the optimal distance between scans.
引用
收藏
页码:653 / 657
页数:5
相关论文
共 18 条
  • [1] AUTOMATED IN-VIVO QUANTIFICATION OF EMPHYSEMA
    ARCHER, DC
    COBLENTZ, CL
    DEKEMP, RA
    NAHMIAS, C
    NORMAN, G
    [J]. RADIOLOGY, 1993, 188 (03) : 835 - 838
  • [2] BERGIN C, 1986, AM REV RESPIR DIS, V133, P541
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] WHOLE LUNG SECTIONS FOR COMPUTED TOMOGRAPHIC PATHOLOGICAL CORRELATIONS - MODIFIED GOUGH-WENTWORTH TECHNIQUE
    GEVENOIS, PA
    KOOB, MC
    JACOBOVITZ, D
    DEVUYST, P
    YERNAULT, JC
    STRUYVEN, J
    [J]. INVESTIGATIVE RADIOLOGY, 1993, 28 (03) : 242 - 246
  • [5] GEVENOIS PA, 1995, IN PRESS J CLIN PATH
  • [6] GOUGH J., 1949, JOUR ROY MICROSC SOC, V69, P231
  • [7] CT MEASUREMENTS OF LUNG DENSITY IN LIFE CAN QUANTITATE DISTAL AIRSPACE ENLARGEMENT - AN ESSENTIAL DEFINING FEATURE OF HUMAN EMPHYSEMA
    GOULD, GA
    MACNEE, W
    MCLEAN, A
    WARREN, PM
    REDPATH, A
    BEST, JJK
    LAMB, D
    FLENLEY, DC
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 137 (02): : 380 - 392
  • [8] HIGH-RESOLUTION CT-DERIVED MEASURES OF LUNG DENSITY ARE VALID INDEXES OF INTERSTITIAL LUNG-DISEASE
    HARTLEY, PG
    GALVIN, JR
    HUNNINGHAKE, GW
    MERCHANT, JA
    YAGLA, SJ
    SPEAKMAN, SB
    SCHWARTZ, DA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1994, 76 (01) : 271 - 277
  • [9] HIGH-RESOLUTION COMPUTED-TOMOGRAPHY OF INFLATION-FIXED LUNGS - PATHOLOGICAL-RADIOLOGIC CORRELATION OF CENTRILOBULAR EMPHYSEMA
    HRUBAN, RH
    MEZIANE, MA
    ZERHOUNI, EA
    KHOURI, NF
    FISHMAN, EK
    WHEELER, PS
    DUMLER, JS
    HUTCHINS, GM
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 136 (04): : 935 - 940
  • [10] SEMIAUTOMATIC EVALUATION PROCEDURES FOR QUANTITATIVE CT OF THE LUNG
    KALENDER, WA
    FICHTE, H
    BAUTZ, W
    SKALEJ, M
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (02) : 248 - 255