ATOMIC EMISSION GAS-CHROMATOGRAPHIC DETECTION - CHEMICAL AND SPECTRAL INTERFERENCES IN THE STABILIZED CAPACITIVE PLASMA (SCP)

被引:39
作者
GROSS, R
PLATZER, B
LEITNER, E
SCHALK, A
SINABELL, H
ZACH, H
KNAPP, G
机构
[1] Graz University of Technology, Department of Analytical Chemistry, Micro- and Radiochemistry, A-8010 Graz
关键词
D O I
10.1016/0584-8547(92)80010-E
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The stabilized capacitive plasma (SCP) is a 27 MHz discharge in helium at atmospheric pressure used as atomic emission source for element specific detection (ESD) in gas chromatography. The discharge is sustained in a liquid-cooled fused-silica tube surrounded by two annular electrodes. The introduction of small amounts of various gases (H-2, O2, N2, CO2, Ar) into the helium plasma leads to significant changes in the spectral emission pattern and the emission intensity of important analyte lines. The analytes were introduced into the plasma at constant flow using a diffusion device and by chromatographic separation of test mixtures. Both a monochromator and a polychromator system were used to detect spectral emission in the near-infrared region.
引用
收藏
页码:95 / 106
页数:12
相关论文
共 28 条
[1]   OXYGEN-SELECTIVE MICROWAVE-INDUCED PLASMA GAS-CHROMATOGRAPHY DETECTOR FOR PETROLEUM-RELATED SAMPLES [J].
BRADLEY, C ;
CARNAHAN, JW .
ANALYTICAL CHEMISTRY, 1988, 60 (09) :858-863
[2]   SPECTRA EXCITED IN HELIUM AFTERGLOW [J].
COLLINS, CB ;
ROBERTSON, WW .
JOURNAL OF CHEMICAL PHYSICS, 1964, 40 (03) :701-&
[3]  
ESTES SA, 1981, ANAL CHEM, V53, P1829, DOI 10.1021/ac00235a026
[4]   SELECTIVE DETECTION IN COLUMN CHROMATOGRAPHY [J].
ETTRE, LS .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1978, 16 (09) :396-417
[5]   A LOW-PRESSURE BEENAKKER-TYPE MICROWAVE-INDUCED HELIUM PLASMA SOURCE AS A SIMULTANEOUS MULTIELEMENT GAS-CHROMATOGRAPHIC DETECTOR [J].
EVANS, JC ;
OLSEN, KB ;
SKLAREW, DS .
ANALYTICA CHIMICA ACTA, 1987, 194 :247-260
[6]   LOW CONSTANT VAPOUR CONCENTRATIONS OBTAINED BY A DYNAMIC METHOD BASED ON DIFFUSION [J].
FORTUIN, JMH .
ANALYTICA CHIMICA ACTA, 1956, 15 (06) :521-533
[7]   STUDY OF THE FACTORS INFLUENCING THE DETECTION OF OXYGEN WITH GAS-CHROMATOGRAPHY - MICROWAVE-INDUCED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
GOODE, SR ;
KIMBROUGH, LK .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :915-918
[8]  
GROSS R, 1989, THESIS GRAZ TU GRAZ
[9]   CAPILLARY-GC HELIUM MICROWAVE EMISSION DETECTOR CHARACTERIZATION OF FLUORINE CONTAINING METABOLITES IN BLOOD-PLASMA [J].
HAGEN, DF ;
BELISLE, J ;
MARHEVKA, JS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1983, 38 (1-2) :377-385
[10]   MOLECULAR FORMULA DETERMINATION OF CAPILLARY COLUMN GAS-CHROMATOGRAPHIC EFFLUENTS USING COMBINED MICROWAVE-INDUCED PLASMA EMISSION AND MASS-SPECTRAL DATA [J].
HOOKER, DB ;
DEZWAAN, J .
ANALYTICAL CHEMISTRY, 1989, 61 (19) :2207-2211