ULTRA-TRACE DETERMINATION OF CADMIUM BY VAPOR GENERATION ATOMIC FLUORESCENCE SPECTROMETRY

被引:49
作者
EBDON, L
GOODALL, P
HILL, SJ
STOCKWELL, PB
THOMPSON, KC
机构
[1] PS ANALYT,SEVENOAKS TN15 6QY,ENGLAND
[2] YORKSHIRE WATER,LABSERV,SHEFFIELD S2 4EQ,ENGLAND
关键词
CADMIUM; VAPOR GENERATION; ETHYLATION; ATOMIC FLUORESCENCE SPECTROMETRY; ATOMIC ABSORPTION SPECTROMETRY;
D O I
10.1039/ja9930800723
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The vapour generation of cadmium by reaction in aqueous solution with sodium tetraethylborate was performed using a conventional continuous flow reactor. This vapour generation system was successfully interfaced with atomic absorption and fluorescence instrumentation. A detection limit, with fluorescence detection, of 20 ng dm-3 (3sigma(n-1)) was obtained after optimization of the chemistry using simplex routines. Interferences from transition metal ions (e.g., Ni(II), Cu(II)) were observed but were attenuated by the use of citrate as a masking agent. Vapour generation atomic fluorescence spectrometry was successfully applied to the determination of cadmium in potable waters, a National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 1643c Trace Elements in H2O, and Community Bureau of Reference (BCR) Certified Reference Materials (CRMs) 144 Sewage Sludge-domestic and 145 Sewage Sludge-industrial. Full recovery of cadmium spikes was obtained from UK drinking waters. A value of 12.6 +/- 0.5 ng cm-3 of cadmium was obtained for NIST SRM 1643c (certificate value = 12.2 +/- 0.1 ng cm-3 of cadmium) whilst the cadmium content of BCR 144 and 145 (certificate value 3.41 +/- 0.25 and 18.0 +/- 1.2 mug g-1, respectively) was estimated at 3.34 +/- 0.15 mug g-1 (BCR 144) and 18.24 +/- 0.7 mug g-1 (BCR 145).
引用
收藏
页码:723 / 729
页数:7
相关论文
共 18 条
[1]   METHODS FOR THE PRODUCTION OF VOLATILE ORGANOMETALLIC DERIVATIVES FOR APPLICATION TO THE ANALYSIS OF ENVIRONMENTAL-SAMPLES [J].
ASHBY, J ;
CLARK, S ;
CRAIG, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (05) :735-736
[2]   SPECIATION FOR ANALYSIS OF ORGANOTIN COMPOUNDS BY GC AA AND GC MS AFTER ETHYLATION BY SODIUM TETRAETHYLBORATE [J].
ASHBY, JR ;
CRAIG, PJ .
APPLIED ORGANOMETALLIC CHEMISTRY, 1991, 5 (03) :173-181
[4]   DETERMINATION OF ARSENIC BY HYDRIDE GENERATION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY USING A TUBULAR MEMBRANE GAS-LIQUID SEPARATOR [J].
BRANCH, S ;
CORNS, WT ;
EBDON, L ;
HILL, S ;
ONEILL, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (02) :155-158
[5]   GENERATION OF A VOLATILE CADMIUM SPECIES IN AN ORGANIC MEDIUM [J].
CACHO, J ;
BELTRAN, I ;
NERIN, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (07) :661-663
[6]   VOLATILIZATION OF COBALT CHELATES FOR THEIR DIRECT INTRODUCTION IN THE VAPOR-PHASE IN FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
CASTILLO, JR ;
DELFA, J ;
MIR, JM ;
BENDICHO, C ;
DELAGUARDIA, M ;
MAURI, AR ;
MONGAY, C ;
MARTINEZ, E .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (04) :325-330
[7]   DEVELOPMENT OF AN ATOMIC FLUORESCENCE SPECTROMETER FOR THE HYDRIDE-FORMING ELEMENTS [J].
CORNS, WT ;
STOCKWELL, PB ;
EBDON, L ;
HILL, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :71-77
[9]   DETERMINATION OF CADMIUM IN AQUEOUS SAMPLES BY VAPOR GENERATION WITH SODIUM TETRAETHYLBORATE(III) REAGENT [J].
DULIVO, A ;
CHEN, YW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (04) :319-322
[10]   ATOMIC FLUORESCENCE SPECTROMETRIC DETERMINATION OF MERCURY USING A FILTER FLUORIMETER [J].
GODDEN, RG ;
STOCKWELL, PB .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (03) :301-303