CONVERSION RATES OF INDUCED VERSUS SPONTANEOUS VENTRICULAR-TACHYCARDIA BY A 3RD GENERATION CARDIOVERTER DEFIBRILLATOR

被引:25
作者
PORTERFIELD, JG
PORTERFIELD, LM
SMITH, BA
BRAY, L
VOSHAGE, L
MARTINEZ, A
AKHTAR, M
BATSFORD, B
CANNON, D
FOGOROS, R
GUARNIERI, T
HAINES, D
HERRE, J
HIGGINS, S
PORTERFIELD, JG
PORTERFIELD, LM
SMITH, BA
BRAY, L
VOSHAGE, L
MARTINEZ, A
HOROWITZ, L
IRWIN, J
LEVINE, J
MALONEY, J
MORADY, F
MYERBURG, R
PORTERFIELD, J
PRYSTOWSKY, E
VELTRI, E
WHARTON, M
WINKLE, R
ZIMMERMAN, J
机构
[1] UNIV TENNESSEE CTR HLTH SCI,MEMPHIS,TN 38163
[2] METHODIST HOSP,MEMPHIS,TN 38104
[3] CARDIAC PACEMAKERS INC,ST PAUL,MN
[4] YALE NEW HAVEN MED CTR,NEW HAVEN,CT 06504
[5] ALLEGHENY GEN HOSP,PITTSBURGH,PA 15212
[6] JOHNS HOPKINS UNIV HOSP,BALTIMORE,MD 21205
[7] UNIV VIRGINIA HOSP,CHARLOTTESVILLE,VA 22908
[8] CLEVELAND CLIN EDUC FDN,CLEVELAND,OH 44106
[9] SINAI SAMARITAN MED CTR,MILWAUKEE,WI
[10] SENTARA NORFOLK GEN HOSP,NORFOLK,VA
[11] UNIV MICHIGAN HOSP,ANN ARBOR,MI 48109
[12] JACKSON MEM HOSP,MIAMI,FL 33136
[13] ST JOSEPHS HOSP,TAMPA,FL
[14] ST FRANCIS HOSP,ROSLYN,NY
[15] SINAI HOSP,BALTIMORE,MD 21215
[16] SCRIPPS MEM,LA JOLLA,CA
[17] PRESBYTERIAN MED CTR,PHILADELPHIA,PA
[18] ST VINCENT HOSP,INDIANAPOLIS,IN
[19] DUKE UNIV HOSP,DURHAM,NC
[20] SEQUOIA HOSP,PALO ALTO,CA
[21] HACKENSACK MED CTR,HACKENSACK,NJ
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1993年 / 16卷 / 01期
关键词
ANTITACHYCARDIA PACING; PACEMAKER CARDIOVERTER DEFIBRILLATOR;
D O I
10.1111/j.1540-8159.1993.tb01556.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Seventy consecutive patients received the first VENTAK PRx pulse generators (Cardiac Pacemakers, Inc.) implanted in the United States. This multiprogrammable device has therapeutic options that include: (1) antitachycardia pacing; (2) low energy cardioversion; (3) defibrillation shocks; and (4) bradycardia pacing. There were 60 males and 10 females with a mean age of 65.3 +/- 9.4 years. The anatomical diagnoses were coronary artery disease in 55 patients, cardiomyopathy in 7 patients, congenital heart disease in 2 patients, and miscellaneous disease in the remaining 6 patients. Thirty-six percent had a history of sudden cardiac death and 90% had documented monomorphic ventricular tachycardia. The mean ejection fraction was 32.7% +/- 12.2%. Thirty-three (49.3%) had an ejection fraction less-than-or-equal-to 30%. Electrophysiological testing was done preimplant, predischarge, and 1 to 2 months postimplant to define a specific electrical therapy and evaluate the efficacy of the device. Two hundred ninety-three of 367 (80%) episodes of induced ventricular tachycardia were successfully terminated by the VENTAK PRx programmed for antitachycardia pacing. There were 1,794 total therapy episodes for spontaneous ventricular tachycardia; 91% (1,641 episodes) were terminated by antitachycardia pacing and 153 episodes were converted by shocks during a minimal 6-month follow-up per patient. We conclude that documentation of a successful antitachycardia pacing modality in the electrophysiology laboratory predicts conversion of spontaneous episodes of ventricular tachycardia. Furthermore, antitachycardia pacing by the VENTAK PRx can terminate the majority of episodes of ventricular tachycardia.
引用
收藏
页码:170 / 173
页数:4
相关论文
共 6 条
[1]   TERMINATION OF VENTRICULAR TACHYCARDIA WITH BURSTS OF RAPID VENTRICULAR PACING [J].
FISHER, JD ;
MEHRA, R ;
FURMAN, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (01) :94-102
[2]   DETERMINANTS OF PACE-TERMINABLE VENTRICULAR-TACHYCARDIA - IMPLICATIONS FOR IMPLANTABLE ANTITACHYCARDIA DEVICES [J].
IP, JH ;
WINTERS, SL ;
SCHWEITZER, P ;
LOTVIN, A ;
TEPPER, D ;
GOMES, AJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11) :1777-1781
[3]   REDUCTION IN DEFIBRILLATOR SHOCKS WITH AN IMPLANTABLE DEVICE COMBINING ANTITACHYCARDIA PACING AND SHOCK THERAPY [J].
LEITCH, JW ;
GILLIS, AM ;
WYSE, DG ;
YEE, R ;
KLEIN, GJ ;
GUIRAUDON, G ;
SHELDON, RS ;
DUFF, HJ ;
KIESER, TM ;
MITCHELL, LB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (01) :145-151
[4]   IMPROVED PATIENT SURVEILLANCE AND DATA ACQUISITION WITH A 3RD GENERATION IMPLANTABLE CARDIOVERTER DEFIBRILLATOR [J].
LUCERI, RM ;
PUCHFERRAN, RL ;
BROWNSTEIN, SL ;
HABAL, SM ;
DAVID, IB ;
VARDEMAN, LL .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (11) :1870-1874
[5]   96 EPISODES OF SPONTANEOUS VENTRICULAR-TACHYCARDIA IN 1 WEEK - SUCCESS OF RAMP PACING BY A PACER-CARDIOVERTER-DEFIBRILLATOR [J].
PORTERFIELD, JG ;
PORTERFIELD, LM ;
BRAY, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (10) :1440-1443
[6]  
YEE R, 1990, CAN J CARDIOL, V6, P147