CAROTID-CNS MR FLOW IMAGING

被引:32
作者
MASARYK, TJ
LAUB, GA
MODIC, MT
ROSS, JS
HAACKE, EM
机构
[1] CASE WESTERN RESERVE UNIV HOSP,DEPT RADIOL,CLEVELAND,OH 44106
[2] SIEMENS MED SYST INC,ERLANGEN,GERMANY
关键词
D O I
10.1002/mrm.1910140215
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors present their 1‐year experience with the use of 3DFT, time‐of‐flight MR angiography for the evaluation of vascular diseases of the head and neck. Their experience with over 150 patients indicates that this examination may be performed in conjunction with standard spin‐echo imaging with only a minimal increase in patient examination time. This combined examination is most applicable to atherosclerotic disease of the carotid bifurcation, arterial occlusions of the primary and secondary branches of the intracranial circulation (particularly in pediatric patients such as those following ECMO or with sickle cell anemia), and patients with saccular berry aneurysms. This type of static, angiographic technique adds little to standard spin‐echo imaging in patients with arteriovenous fistulae, neoplasms, and giant intracranial aneurysms. Limitations of the present technique include the inability to visualize slow flow lesions (e.g., giant aneurysms) and selected high flow states (arteriovenous fistulae, some severe stenoses ). © 1990 Academic Press, Inc. Copyright © 1990 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:308 / 314
页数:7
相关论文
共 12 条
[1]   MR ANGIOGRAPHY OF PERIPHERAL, CAROTID, AND CORONARY-ARTERIES [J].
ALFIDI, RJ ;
MASARYK, TJ ;
HAACKE, EM ;
LENZ, GW ;
ROSS, JS ;
MODIC, MT ;
NELSON, AD ;
LIPUMA, JP ;
COHEN, AM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (06) :1097-1109
[2]   FRODO PULSE SEQUENCES - A NEW MEANS OF ELIMINATING MOTION, FLOW, AND WRAPAROUND ARTIFACTS [J].
EDELMAN, RR ;
ATKINSON, DJ ;
SILVER, MS ;
LOAIZA, FL ;
WARREN, WS .
RADIOLOGY, 1988, 166 (01) :231-236
[3]   EFFECTS OF TURBULENCE ON SIGNAL INTENSITY IN GRADIENT ECHO IMAGES [J].
EVANS, AJ ;
BLINDER, RA ;
HERFKENS, RJ ;
SPRITZER, CE ;
KUETHE, DO ;
FRAM, EK ;
HEDLUND, LW .
INVESTIGATIVE RADIOLOGY, 1988, 23 (07) :512-518
[4]  
HAACKE EM, 1989, IEEE ASS APR
[5]  
HOHNE KH, 1987, P CAR 87, P599
[6]  
KONIG HA, 1988, IN PRESS ELECTROMEDI, V56
[7]   MR ANGIOGRAPHY WITH GRADIENT MOTION REFOCUSING [J].
LAUB, GA ;
KAISER, WA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (03) :377-382
[8]   INPLANE VASCULAR IMAGING - PULSE SEQUENCE DESIGN AND STRATEGY [J].
LENZ, GW ;
HAACKE, EM ;
MASARYK, TJ ;
LAUB, G .
RADIOLOGY, 1988, 166 (03) :875-882
[9]   CAROTID BIFURCATION - MR IMAGING - WORK IN PROGRESS [J].
MASARYK, TJ ;
ROSS, JS ;
MODIC, MT ;
LENZ, GW ;
HAACKE, EM .
RADIOLOGY, 1988, 166 (02) :461-466
[10]   VERIFICATION AND EVALUATION OF INTERNAL FLOW AND MOTION - TRUE MAGNETIC-RESONANCE IMAGING BY THE PHASE GRADIENT MODULATION METHOD [J].
MORAN, PR ;
MORAN, RA ;
KARSTAEDT, N .
RADIOLOGY, 1985, 154 (02) :433-441