SCINTIGRAPHIC DETECTION OF SPLENOSIS - SUPERIORITY OF TOMOGRAPHIC SELECTIVE SPLEEN SCINTIGRAPHY

被引:65
作者
GUNES, I [1 ]
YILMAZLAR, T [1 ]
SARIKAYA, I [1 ]
AKBUNAR, T [1 ]
IRGIL, C [1 ]
机构
[1] ULUDAG UNIV HOSP,DEPT GEN SURG,BURSA,TURKEY
关键词
D O I
10.1016/S0009-9260(05)83452-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
We used Scintigraphy with sulphur colloid and heat-damaged red cells to detect splenosis after splenectomy in 19 patients 7 to 69 months after injury. We compared planar and tomographic selective spleen scintigraphy using heat-damaged red cells with subtracted planar colloid scintigraphy, and showed that the most sensitive method was tomographic selective splenic scintigraphy. The incidence of splenosis was 58% with this method, the other techniques detecting abnormalities in 21% and 26% of the patients.
引用
收藏
页码:115 / 117
页数:3
相关论文
共 21 条
[1]
CLINICAL-STUDIES WITH SPLEEN-SPECIFIC RADIOLABELED AGENTS [J].
ARMAS, RR .
SEMINARS IN NUCLEAR MEDICINE, 1985, 15 (03) :260-275
[2]
ARMAS RR, 1980, J NUCL MED, V21, P413
[3]
RADIOPHARMACEUTICALS FOR SPLEEN AND BONE-MARROW STUDIES [J].
DESAI, AG ;
THAKUR, ML .
SEMINARS IN NUCLEAR MEDICINE, 1985, 15 (03) :229-238
[4]
DESTABLE M D, 1989, Revue de Pneumologie Clinique, V45, P34
[5]
ERASMIE U, 1988, ACTA RADIOL, V29, P121
[6]
GIRVAN DP, 1984, CAN J SURG, V27, P539
[7]
JACOBSON SJ, 1971, J NUCL MED, V12, P570
[8]
LIVINGSTON CD, 1983, ARCH SURG-CHICAGO, V118, P617
[9]
LUDTKE FE, 1989, ACTA CHIR SCAND, V155, P533
[10]
MASSEY MD, 1991, J NUCL MED, V32, P2286