TREATMENT PLANNING OPTIMIZATION FOR MULTIPLE ARCS STEREOTAXIC RADIOSURGERY USING A LINEAR-ACCELERATOR

被引:9
作者
LAM, CF
ZHU, JG
PENN, JO
JENRETTE, JM
机构
[1] MED UNIV S CAROLINA,DEPT RADIOL,CHARLESTON,SC 29425
[2] MED UNIV S CAROLINA,DEPT RADIAT & ONCOL,CHARLESTON,SC 29425
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 33卷 / 03期
关键词
MULTIARC RADIOSURGERY; 3D TREATMENT PLANNING; NONLINEAR SIMPLEX OPTIMIZATION;
D O I
10.1016/0360-3016(95)00224-M
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Multiarc stereotactic radiosurgery is a technique used to irradiate an intracranial tumor with minimal damage to the surrounding normal tissue. The purpose of this paper is to present a method for and the results from optimizing three dimensional (3D) treatment dose for multiarc stereotactic radiosurgery. Methods and Materials: The normal procedure for a physician-physicist team designing a treatment plan for multiarc stereotactic radiosurgery is the trial-and-error approach of changing the collimator size and the isocenter of radiation by viewing the isodose curves on a two dimensional (2D) computed tomography (CT) or magnetic resonance imaging (MRI) image plane, Not only is this time consuming, but the resulting treatment plan is not optimal in most, if not all, cases, One reason for such nonconformal isodose curves is that the same collimator size is used for all arcs, However, it is very difficult to determine manually the different collimator sizes for different arcs, A derivative free optimization method is used to optimize the collimator size for each are, as well as the 3D coordinates of the isocenter(s). Results: One spherical and two ellipsoidal artificial tumors, and one actual tumor, were used to show the utilities of the optimization process, The 90% isodose curves resulting from optimization conform very well with the tumor; whereas the 90% isodose curves from the conventional method either do not envelop the entire tumor when the collimator size is too small, or a large volume of normal tissue is also irradiated by the 90% dose when the next larger collimator size is used. Conclusions: When the collimator size for each are and the location of the isocenters(s) are optimized in a multiarc stereotactic surgery treatment plan, the 90% isodose curve conforms to the tumor much better than when the same collimator size is used for all arcs.
引用
收藏
页码:647 / 657
页数:11
相关论文
共 24 条
[1]  
Alexander E, 1993, STEREOTACTIC RADIOSU
[2]   STEREOTACTIC RADIOSURGERY WITH THE LINEAR-ACCELERATOR - TREATMENT OF ARTERIOVENOUS-MALFORMATIONS [J].
BETTI, OO ;
MUNARI, C ;
ROSLER, R .
NEUROSURGERY, 1989, 24 (03) :311-321
[3]  
Bjarngard B E, 1990, MED PHYS, V17, P795
[4]  
Colombo F, 1989, J Neurosurg Sci, V33, P123
[5]   LINEAR-ACCELERATOR RADIOSURGERY OF CEREBRAL ARTERIOVENOUS-MALFORMATIONS [J].
COLOMBO, F ;
BENEDETTI, A ;
POZZA, F ;
MARCHETTI, C ;
CHIEREGO, G .
NEUROSURGERY, 1989, 24 (06) :833-840
[6]   TREATMENT PLANNING FOR STEREOTAXIC RADIOSURGERY OF INTRACRANIAL LESIONS [J].
KOOY, HM ;
NEDZI, LA ;
LOEFFLER, JS ;
ALEXANDER, E ;
CHENG, CW ;
MANNARINO, EG ;
HOLUPKA, EJ ;
SIDDON, RL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (03) :683-693
[7]   HIGH-ENERGY PROTON BEAM AS A NEUROSURGICAL TOOL [J].
LARSSON, B ;
LEKSELL, L ;
REXED, B ;
SOURANDER, P ;
MAIR, W ;
ANDERSSON, B .
NATURE, 1958, 182 (4644) :1222-1223
[8]  
LEKSELL L, 1971, STEREOTAXIS RADIOSUR
[9]   STEREOTACTIC RADIOSURGERY FOR INTRACRANIAL ARTERIOVENOUS-MALFORMATIONS USING A STANDARD LINEAR-ACCELERATOR [J].
LOEFFLER, JS ;
ALEXANDER, E ;
SIDDON, RL ;
SAUNDERS, WM ;
COLEMAN, CN ;
WINSTON, KR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (03) :673-677
[10]  
LUNSFORD LD, 1989, NEUROSURGERY, V24, P151