A CARBON-FIBER IMPLANT TO AID INTERBODY LUMBAR FUSION - 2-YEAR CLINICAL-RESULTS IN THE 1ST 26 PATIENTS

被引:393
作者
BRANTIGAN, JW
STEFFEE, AD
机构
[1] Department of Surgery, Division of Orthopaedics, Creighton University, Omaha, NE
[2] Cleveland Spine and Arthritis Center, Cleveland, OH
关键词
INTERBODY FUSION; PLIF; ALIF; CARBON CAGE; ALLOGRAFT; PEDICLE SCREW;
D O I
10.1097/00007632-199310001-00030
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The success of posterior lumbar interbody fusion (PLIF) has been limited by mechanical and biologic deficiencies of the donor bone. The authors have designed a carbon fiber-reinforced polymer implant that separates the mechanical and biologic functions of PLIF. The cagelike implant provides an actual device designed to meet the mechanical requirements of PLIF and replaces the donor bone with autologous bone, the best possible bone for healing. The authors report 2-year follow-up results for their first 26 consecutive patients, 18 of whom were postsurgical failed backs with a total of 37 previous surgeries. At 2 years, 28 of 28 PLIF cage fusion levels and 6 of 11 (54.5%) allograft levels exhibited radiographic fusion, a statistically significant difference at P = 0.0002. Clinical results were excellent in 11/26, good in 10/26, fair in 3/26, and poor in 2/26. Fair and poor results were attributable to objective identifiable problems unrelated to the carbon cage. The carbon implant achieved successful fusion in 6/6 (100%) of followed patients treated for a failed ETO allograft interbody fusion. A prospective controlled multi-centered study is being initiated.
引用
收藏
页码:2106 / 2117
页数:12
相关论文
共 33 条
  • [1] Brantigan J.W., Cunningham B.W., Warden K., McAfee P.C., Steffee A.D., Compression Strength of Allograft Bone for PLIF
  • [2] Brantigan J.W., Cunningham B.W., Warden K., McAfee P.C., Steffee A.D., Interbody Lumbar Fusion Using a Carbon Fiber Cage Implant Vs. Allograft Bone-An Investigational Study in the Spanish Goat
  • [3] Brantigan J.W., Steffee A.D., Keppler L., Biscup R.S., Enker P., Posterior lumbar interbody fusion technique using the Variable Screw Placement Spinal Fixation System, Spine, 6, pp. 175-200, (1992)
  • [4] Brantigan J.W., Steffee A.D., Geiger J.M., A carbon fiber implant to aid interbody lumbar fusion: Mechanical testing, Spine, 16, (1991)
  • [5] Brodsky A.E., Kovalsky E.S., Khalil M.A., Correlation of radiologic assessment of lumbar spine fusions with surgical exploration, Spine, 16, (1991)
  • [6] Chow S.P., Leong J., Ma A., Yau A., Anterior spinal fusion for deranged lumbar intervertebral discs: A review of 97 cases, Spine, 5, pp. 452-458, (1980)
  • [7] Christel P.S., The applications of carbon fiber-reinforced carbon composites (CRFC) in orthopaedic surgery, CRC Critical Reviews in Biocompatibility, 2, 3, pp. 189-218, (1986)
  • [8] Cleveland M., Bosworth D.M., Thompson F.R., Pseudarthrosis in the lumbosacral spine, J Bone Join T Surg, 30A, pp. 302-312, (1948)
  • [9] Cloward R.B., The treatment of ruptured lumbar intervertebral discs by vertebral body fusion, J Neurosurg, 10, (1953)
  • [10] Cloward R.B., Posterior lumbar interbody fusion updated, Clin Orthop, 193, pp. 16-19, (1985)