EVALUATION OF METABOLIC MEASURING-INSTRUMENTS FOR USE IN CRITICALLY ILL PATIENTS

被引:92
作者
MAKITA, K [1 ]
NUNN, JF [1 ]
ROYSTON, B [1 ]
机构
[1] CLIN RES CTR,DIV ANESTHESIA,WATFORD RD,HARROW HA1 3UJ,MIDDX,ENGLAND
关键词
D O I
10.1097/00003246-199006000-00013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
We evaluated three commercial indirect calorimetry devices which are used during artificial ventilation. Commercial butane, which had an RQ of 0.615, consumes 6.40 ml oxygen, and produces 3.94 ml CO2/1 ml, was burned in a gas-tight combustion chamber in conjunction with the ventilation of a lung model. During combustion, the flow rate of butane was measured with a soapfilm flowmeter for the calculation of reference values of oxygen consumption (V̇O2) and CO2 production (V̇CO2). To investigate the effect of oxygen concentration on the accuracy of these instruments, measurements were carried out at FIO2 values of 0.3, 0.4, 0.5, and 0.6 with a fixed ventilation mode (tidal volume 500 ml; respiratory rate 16 breath/min, intermittent positive-pressure ventilation). For the Datex Deltatrac Metabolic Monitor, the mean relative errors of measured V̇O2, V̇CO2, and RQ were all within 4.0%, 2.9%, and 4.0%, respectively. For the Engstrom Metabolic Computer, the corresponding values were 1.4%, 5.7%, and 6.0%, and for the SensorMedics MMC Horizon, 5.7%, 2.9%, and 5.9%.
引用
收藏
页码:638 / 644
页数:7
相关论文
共 20 条
  • [1] RESPIRATORY CHANGES INDUCED BY THE LARGE GLUCOSE LOADS OF TOTAL PARENTERAL-NUTRITION
    ASKANAZI, J
    ROSENBAUM, SH
    HYMAN, AI
    SILVERBERG, PA
    MILICEMILI, J
    KINNEY, JM
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1980, 243 (14): : 1444 - 1447
  • [2] BARTELS H, 1963, METHODS PULMONARY PH, P45
  • [3] CONTINUOUS MEASUREMENT OF OXYGEN-UPTAKE - EVALUATION OF THE ENGSTROM METABOLIC COMPUTER AND CLINICAL-EXPERIENCES
    BEHRENDT, W
    WEILAND, C
    KALFF, J
    GIANI, G
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1987, 31 (01) : 10 - 14
  • [4] EVALUATION OF METHODS FOR INDIRECT CALORIMETRY WITH A VENTILATED LUNG MODEL
    BRAUN, U
    ZUNDEL, J
    FREIBOTH, K
    WEYLAND, W
    TURNER, E
    HEIDELMEYER, CF
    HELLIGE, G
    [J]. INTENSIVE CARE MEDICINE, 1989, 15 (03) : 196 - 202
  • [5] BROWNING JA, 1982, CRIT CARE MED, V10, P8212
  • [6] A SYSTEMATIC METHOD FOR VALIDATION OF GAS-EXCHANGE MEASUREMENTS
    DAMASK, MC
    WEISSMAN, C
    ASKANAZI, J
    HYMAN, AI
    ROSENBAUM, SH
    KINNEY, JM
    [J]. ANESTHESIOLOGY, 1982, 57 (03) : 213 - 218
  • [7] DAVIES GG, 1985, ANESTHESIOLOGY, V63, pA171
  • [8] DE V, 1949, J PHYSL, V109, P1
  • [9] CALCULATION OF SUBSTRATE OXIDATION RATES INVIVO FROM GASEOUS EXCHANGE
    FRAYN, KN
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (02) : 628 - 634
  • [10] EVALUATION OF A MICROPROCESSOR-CONTROLLED EXERCISE TESTING SYSTEM
    JONES, NL
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1984, 57 (05) : 1312 - 1318