MR IMAGING IN ASSESSMENT OF CARDIAC TRANSPLANT REJECTION IN HUMANS

被引:26
作者
DOORNBOS, J
VERWEY, H
ESSED, CE
BALK, AHMM
DEROOS, A
机构
[1] UNIV HOSP LEIDEN,DEPT CARDIOL,2300 RC LEIDEN,NETHERLANDS
[2] ROTTERDAM UNIV HOSP,DEPT PATHOL,ROTTERDAM,NETHERLANDS
[3] ERASMUS UNIV,HOSP DIJKZIGT,CTR THORAX,ROTTERDAM,NETHERLANDS
[4] INTERUNIV,CARDIOL INST,UTRECHT,NETHERLANDS
关键词
Biopsies; Heart; failure; transplant; Magnetic resonance imaging; techniques;
D O I
10.1097/00004728-199001000-00012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the efficacy of myocardial T2 values in the assessment of allograft rejection, we performed magnetic resonance (MR) imaging at 0.5 T serially in seven cardiac transplant recipients and singly in seven normal volunteers. Cardiac-gated multiecho spin echo images were obtained; T2 values were estimated by a two-point method from regions of interest in the myocardium. Patients underwent MR and cardiac biopsy at various times after transplantation. Forty-two patient exams were performed. All biopsies showed either no rejection or early stages of rejection: Grade 0 in 8 examinations, grade 1 in 28, and grade 2 in 6. Myocardial T2 values in patients in early stages of cardiac rejection were slightly higher (but not statistically significant) than those in nonrejecting patients and normal volunteers. Although this study did not allow prospective detection of cardiac rejection in our patient group, it demonstrated a trend toward higher T2 values at higher biopsy grades that may indicate an ability to assess more severe stages of transplant rejection. © 1990 Raven Press, Ltd., New York.
引用
收藏
页码:77 / 81
页数:5
相关论文
共 11 条
[1]   MAGNETIC-RESONANCE-IMAGING OF CARDIAC TRANSPLANTS - THE EVALUATION OF REJECTION OF CARDIAC ALLOGRAFTS WITH AND WITHOUT IMMUNOSUPPRESSION [J].
AHERNE, T ;
TSCHOLAKOFF, D ;
FINKBEINER, W ;
SECHTEM, U ;
DERUGIN, N ;
YEE, E ;
HIGGINS, CB .
CIRCULATION, 1986, 74 (01) :145-156
[2]  
Billingham ME., 1982, HEART TRANSPLANTATIO, V1, P25
[3]  
BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
[4]  
EUGENE M, 1985, J HEART TRANSPLANT, V5, P39
[5]  
HALL TS, 1986, HEART TRANSPLANT, V5, P416
[6]   ACCURACY AND REPRODUCIBILITY OF IMAGE DERIVED RELAXATION-TIMES ON A CLINICAL 1.5-T MAGNETIC-RESONANCE SCANNER [J].
MASTERSON, ME ;
MCGARY, R ;
SCHMITT, K ;
KOUTCHER, JA .
MEDICAL PHYSICS, 1989, 16 (02) :225-233
[7]  
MOSS AA, 1989, INVEST RADIOL, V24, P508
[8]  
NISHIMURA T, 1987, Heart and Vessels, V3, P135, DOI 10.1007/BF02058789
[9]   CARDIAC T1 CALCULATIONS FROM MR SPIN-ECHO IMAGES [J].
PRATO, FS ;
DROST, DJ ;
KING, M ;
KEYS, T ;
WISENBERG, G ;
GALLAND, C ;
PFLUGFELDER, PW .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (03) :227-243
[10]  
SIMONSON T, 1989, Journal of the American College of Cardiology, V13, p201A