EXPERIMENTAL-STUDY OF FULL-SIZE AUTOMATED VENETIAN BLIND WINDOWS

被引:15
作者
RHEAULT, S
BILGEN, E
机构
[1] Ecole Polytechnique, Montreal
关键词
D O I
10.1016/0038-092X(90)90079-R
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study presents an experimental study on full-size automated venetian blind window systems consisting of horizontal pivoted louvers installed and hermetically sealed between two glass panes. The experimental study was carried out using a test cell of 2.43 m high, 1.48 m wide, and 1.92 m deep. Various parameters were measured instantaneously and recorded using a data acquisition system: interior and exterior air temperatures; various surface temperatures; and total and direct solar radiations. A linearized numerical model was used to verify the experimental results. © 1990.
引用
收藏
页码:157 / 160
页数:4