DOPPLER WAVE-FORMS IN THE RENAL-ARTERIES OF NORMAL-CHILDREN

被引:8
作者
FRIEDMAN, DM [1 ]
SCHACHT, RG [1 ]
机构
[1] NYU MED CTR, DEPT PEDIAT, NEW YORK, NY 10016 USA
关键词
DOPPLER WAVE-FORMS; RENAL ARTERY; PEDIATRICS;
D O I
10.1002/jcu.1870190704
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Blood velocity waveforms in peripheral arteries vary such that decreasing vascular resistance results in a relative increase in diastolic velocity at steady state. We measured blood velocity in renal arteries of 20 children (age: 119 months +/- 37 months; weight: 38 kg +/- 15 kg) to establish normal values, and to explore the relationship between these waveforms and central hemodynamics. Using image-directed pulsed Doppler echocardiography, M-mode measurements and cardiac index were recorded. Renal hila were visualized via the flank for Doppler sampling. Peak systolic velocity (A) and minimal diastolic velocity (B) were determined. The results (mean +/- SD) were as follows: Renal artery A/B = 2.9 +/- 0.74 (range 1.9 to 5.1). Characteristic waveforms were identical bilaterally and had continuous diastolic foward flow: A/B was independent of central hemodynamics within the resting normal range, varying inversely with age and size.
引用
收藏
页码:387 / 392
页数:6
相关论文
共 35 条
[1]   NON-INVASIVE PULSED DOPPLER DETERMINATION OF CARDIAC-OUTPUT IN NEONATES AND CHILDREN [J].
ALVERSON, DC ;
ELDRIDGE, M ;
DILLON, T ;
YABEK, SM ;
BERMAN, W .
JOURNAL OF PEDIATRICS, 1982, 101 (01) :46-50
[2]  
ALVERSON DC, 1983, PULSED DOPPLER ULTRA, P173
[3]   NONINVASIVE DOPPLER ASSESSMENT OF HUMAN POSTPRANDIAL RENAL BLOOD-FLOW AND CARDIAC-OUTPUT [J].
AVASTHI, PS ;
GREENE, ER ;
VOYLES, WF .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 252 (06) :F1167-F1174
[4]   NONINVASIVE DIAGNOSIS OF RENAL-ARTERY STENOSIS BY ECHO-DOPPLER VELOCIMETRY [J].
AVASTHI, PS ;
VOYLES, WF ;
GREENE, ER .
KIDNEY INTERNATIONAL, 1984, 25 (05) :824-829
[5]   INVESTIGATIONS OF RENAL-ARTERY BLOOD-FLOW VELOCITY IN PRETERM AND TERM NEONATES BY PULSED DOPPLER ULTRASONOGRAPHY [J].
BOMELBURG, T ;
JORCH, G .
EUROPEAN JOURNAL OF PEDIATRICS, 1988, 147 (03) :283-287
[6]   RENAL HEMODYNAMIC-CHANGES IN HUMANS - RESPONSE TO PROTEIN LOADING IN NORMAL AND DISEASED KIDNEYS [J].
BOSCH, JP ;
LEW, S ;
GLABMAN, S ;
LAUER, A .
AMERICAN JOURNAL OF MEDICINE, 1986, 81 (05) :809-815
[7]   RENAL-ARTERY STENOSIS - DUPLEX DOPPLER EVALUATION [J].
DUBBINS, PA .
BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (699) :225-229
[8]   THE EFFECT OF VARIATIONS ON PULSED DOPPLER SAMPLING SITE ON CALCULATION OF CARDIAC-OUTPUT - AN EXPERIMENTAL-STUDY IN OPEN-CHEST DOGS [J].
FISHER, DC ;
SAHN, DJ ;
FRIEDMAN, MJ ;
LARSON, D ;
VALDESCRUZ, LM ;
HOROWITZ, S ;
GOLDBERG, SJ ;
ALLEN, HD .
CIRCULATION, 1983, 67 (02) :370-376
[9]   SUPERIORITY OF TWO-DIMENSIONAL MEASUREMENT OF AORTIC VESSEL DIAMETER IN DOPPLER ECHOCARDIOGRAPHIC ESTIMATES OF LEFT-VENTRICULAR STROKE VOLUME [J].
GARDIN, JM ;
TOBIS, JM ;
DABESTANI, A ;
SMITH, C ;
ELKAYAM, U ;
CASTLEMAN, E ;
WHITE, D ;
ALLFIE, A ;
HENRY, WL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (01) :66-74
[10]   NONINVASIVE DOPPLER ASSESSMENT OF RENAL-ARTERY STENOSIS AND HEMODYNAMICS [J].
GREENE, ER ;
AVASTHI, PS ;
HODGES, JW .
JOURNAL OF CLINICAL ULTRASOUND, 1987, 15 (09) :653-659